6–11
1
2
3
4
5
6
ït
çi
FACSIMILE SYSTEM
3.5
Dial Control
The dial control function generates dial pulses (DP). Application of ON/
OFF switching of
relays
is often adopted as a method of generating dial
pulses. The following shows the basic configuration of the dial control cir-
cuit.
Fig. 6-10 Dial Control Circuit
To generate the dial pulse, the DC loop is formed by the P relay. The dial
pulse is generated by turning this relay ON and OFF. If the S relay remains
ON while the dial pulse is being generated, the pulse waveform is influ-
enced by the DC seize circuit that is located after the S relay, and changes
as follows.
Fig. 6-11 Waveform of Weak Pulse
The waveform changes as follows when the S relay is turned OFF to indi-
cate that it has been shaped.
Fig. 6-12 Waveform of Clear Pulse
DC cut
capacitor
S relay
P relay
DC seize
circuit
L1
L2
+
ON
OFF
Influence of DC seize circuit