6. Memory / Bluetooth / Cable General Setting
6-1-19 StandbyTime
After lengthy idleness, the device will first be put into standby state in which the
machine is still able to react to the emergent request yet running in lower
power consumption. This parameter refers to the amount of time allocated for
the device to stay in standby before being totally shut down..
*8N3+*
Configuration Range
Unit
Default Setting
0 ~ 2550 Secs
10 Sec
30 Secs
6-1-20 Tx Preamble
Preamble Code refers to a sequence of characters which precedes both Prefix
Code and barcode data during data transmission. Scan the appropriate
barcode to enable or disable Preamble Code.
*5W00*
Disable
*5W01*
Enable
Procedure
(A) Scan “Enter” barcode
(B) Scan “StandbyTime” barcode
(C) Scan parameters from Hexadecimal / Decimal table
(D) Scan “OK“ barcode
(E) Scan “End” barcode