7. General Configuration Setting
7-2-2-5 Retransmission Count
To avoid data transmission loss, messages sometimes have to be resent due
to a failure to receive ACK signal; When the amount of resending is out of
range and STILL not yet received ACK, which means Timeout
*58O+*
Procedure:
(A) Scan “Enter” barcode
(B) Scan “Retransmission Count” barcode
(C) Scan parameters from Hexadecimal / Decimal table
(D) Scan “OK“ barcode
(E) Scan “End” barcode
7-2-2-6 ACK Timeout
To set up the period of time to receive ACK after sending data
*68P+*
Procedure:
Example:
(A) Scan “Enter” barcode
(B) Scan “ACK Timeout” barcode
(C) Scan parameters from
Hexadecimal / Decimal table
(D) Scan “OK“ barcode
(E) Scan “End” barcode
If configuration is.2 sec, the
parameter value is
2 sec / 1 sec = 2
Configuration Range
Default Setting
0 ~ 255
2
Configuration Range
Unit
Default Setting
2 ~ 255 secs
1 sec
3 secs