Subsection XX (MAGNETO AND STARTER)
Installing the Magneto Cover
For installation, reverse the removal procedure.
However, pay attention to the following.
Install a
NEW
magneto cover gasket.
Apply
DREI BOND SEALING COMPOUND (P/N 420
297 906)
on stator cable grommet as shown in next
illustration.
tmr2011-012-006_a
1. Stator cable grommet (apply Drei Bond sealing compound)
Tighten screws using the following sequence.
vmr2015-030-003_b
TIGHTENING
S
EQUENCE
TIGHTENING TORQUE
Magneto cover screws
10 N•m ± 1 N•m
(89 lbf•
in
± 9 lbf•
in
)
Refill engine with recommended oil.
STATOR
Stator Connector Access
NOTE:
The stator is directly connected to the volt-
age regulator/rectifier.
vmr2016-403-003_a
vmr2012-014-020_a
1. Voltage regulator/rectifier
2. Three YELLOW wires
Testing the Stator Static Continuity
1. Disconnect the stator connector on the voltage
regulator/rectifier.
REQUIRED TOOL
FLUKE 115 MULTIMETER
(P/N 529 035 868)
2. Set multimeter to
.
3. Connect multimeter between YELLOW wires.
4. Read resistance.
TERMINAL
RESISTANCE @
20°C (68°F)
1 and 2
1 and 3
2 and 3
0.15 - 0.30
4
vmr2016-403