Subsection 05 (STARTING SYSTEM)
Starter Solenoid Control Ground
Circuit
SS1-
SS2-
HIC1-J
ECM
L3
B4
G2
K3
A4
vmr2015-048-005_a
1. Disconnect SS2.
2. Install the ECM connector onto the
ECM
ADAPTER TOOL (P/N 529 036 166)
vmr2008-139-016_a
1. ECM connector
2. ECM adapter tool
PROBE
PROBE
SPECIFICATION
SS2
ECM-L3
Close to 0
If resistance is not as specified, repair or replace
wiring/connections.
If solenoid power control circuit and ground con-
trol circuit both test good, test ECM ground
circuits. Refer to
ELECTRONIC FUEL INJECTION
(EFI)
subsection.
NOTE:
Supply a ground with a jumper wire if you
suspect that the ECM is not supplying a ground to
the solenoid.
Starter Solenoid Continuity
M
BAT1
BAT2
BP
BP1
BP
BP3
vmr2016-136-100_a
1. Disconnect the BLACK (-) negative battery ca-
ble.
2. Disconnect SS1 and SS2
vmr2015-048-012_a
1. SS1
vmr2015-048-003_d
PROBE
PROBE
SPECIFICATION
@ 20°C (68°F)
SS1
SS2
Close to 6
If resistance is not as per specification, replace the
solenoid.
3. Disconnect BP3.
4
vmr2016-136