Visit Us: Camplux.com
3330-A Marathon Ct Charleston, SC 29418
(844) 538-7475
16
● Attach the water output device (shower head) to the fitting marked “Water
outlet”. DO NOT OVER TIGHTEN! Make sure to insert the supplied rubber
gasket at the connections. Tighten by hand only.
● Only use the gas regulator & hose supplied with this appliance.
● A new pressure relief valve, complying with the standard for relief valves and
automatic gas shut-off devices for hot water supply system, ANSI Z21.22/CSA
4.4, must be installed at the hot water outlet connection of the water heater
during installation. Local codes shall govern the installation of any relief valve.
Relief valve is NOT attached with gas water heater.
Water supply installation
1) Install a COLD water shut-off valve near the inlet line on the water heater. This
valve will be used for servicing and draining purpose.
2) Before attaching the water line to the water heater, open the shut-off valve.
Run the water until it has purged all contaminants (sand, debris, air, caulking,
etc).
3) Install a service valve on the end of the COLD water supply line and connect it
to the water inlet on the water heater.
4) Open the shut-off valve in the COLD water inlet line to check the water flow
through the water heater.
5) Close the shut-off valve and remove, clean and replace the water filter.
WARNING
Should overheating occur or the gas supply fails to
shut off, turn off the manual gas control valve to the
appliance.
Pressure Relief Valve
(Not included)
Gas Input
Water inlet
To Hot Water
Faucet(s)
Cold Water Supply
Shut-off Valve
(Water service valve)
Gas Shut-off valve
(Gas service valve)