Section 7. Measurement Instructions
7-8
Parameter
& Data Type
Enter
BRHALF, BRHALF3W, BRHALF4W PARAMETERS
Dest
Variable or
Array
The Variable in which to store the results of the instruction. When Reps are used the results are stored in an
array with the variable name. An array must be dimensioned to have elements for all the Reps.
Reps
Constant
The number of repetitions for the measurement. For analog measurements, entering reps as a negative
number forces all reps to be on the same channel.
Range
The voltage range for the measurement.
Constant
± 5 Volt Analog Input Module
± 50 Volt Analog Input Module
Alpha
Code
Numeric
Code
Voltage
Range
Alpha
Code
Numeric
Code
Voltage
Range
mV5000
0
± 5000 mV
V50
6
± 50 V
mV1000
1
± 1000 mV
V10
7
± 10 V
mV200
4
± 200 mV
V2
10
± 2 V
mV50
5
± 50 mV
mV500
11
± 500 mV
ASlot
Constant
The number of the slot that holds the Analog Input Module to be used for the measurement.
SEChan
Constant
The single-ended channel number on which to make the first measurement. When Reps are used, subsequent
measurements will be automatically made on the following single-ended channels.
ExSlot
Constant
The slot that holds the Excitation Module for the measurement.
ExChan
Constant
Enter the excitation channel number to excite the first measurement.
Channels Result
1 - 6
Continuous analog output channels, will remain at the excitation voltage set by the
instruction unless a subsequent instruction changes their voltage
7 - 16
Switched excitation channels, are switched to the excitation voltage for the
measurement and switched off between measurements.
MesPEx
Constant
The number of sensors to excite with the same excitation channel before automatically advancing to the next
excitation channel. To excite all the sensors with the same excitation channel, the number should equal the
number of Reps.
ExmV
Constant
The excitation voltage in millivolts. Allowable range ± 5000 mV.
RevEx
may be used to excite with both a
positive and negative polarity to cancel offset voltages.
RevEx
Option to reverse excitation to cancel offsets.
Constant
Value Result
0
Excite only with the excitation voltage entered
1
A second measurement is made with the voltage polarity reversed.
RevDiff
Option to reverse inputs to cancel offsets.
Constant
Value Result
0
Signal is measured with the high side referenced to the low
1
A second measurement is made after reversing the inputs
SettlingTime
Constant
The time in microseconds to delay between setting up a measurement (switching to the channel, setting the
excitation) and making the measurement (10 microsecond resolution).
Entry
Voltage Range
Delay
CR9055
Voltage Range
Delay
0
± 50 mV
20 µS (default)
± 500 mV
40 µS (default)
0
± 200 mV
20 µS (default)
± 2 mV
40 µS (default)
0
±1000 mV
10 µS (default)
± 10 mV
30 µS (default)
0
± 5000 mV
10 µS (default)
± 50 mV
30 µS (default)
> 0
All
Truncate to closest 10 µS
all
Truncate to closest 10 µS
Содержание CR9000
Страница 6: ...CR9000 Table of Contents iv This is a blank page ...
Страница 22: ...CR9000 Overview OV 16 This is a blank page ...
Страница 26: ...Section 1 Installation 1 4 CR9000 FIGURE 1 1 3 CR9000 Battery Pack ...
Страница 72: ...Section 3 CR9000 Measurement Details 3 28 This is a blank page ...
Страница 88: ...Section 5 Program Declarations 5 6 This is a blank page ...
Страница 217: ...This is a blank page ...