Section 7. Measurement Instructions
7-4
TCSE (Dest, Reps, Range, ASlot, SEChan, TCType, TRef, SettlingTime,
Integ, Mult, Offset)
S.E. Chanel
Ground
Thermocouple
This instruction measures a thermocouple with a single-ended voltage
measurement and calculates the thermocouple temperature (
°
C) for the
thermocouple type selected. The instruction adds the measured voltage to the
voltage calculated for the reference temperature relative to 0
°
C, and converts
the combined voltage to temperature in
°
C.
Parameter
& Data Type
Enter
VOLTDIFF AND TCDIFF INSTRUCTION PARAMETERS
Dest
Variable or
Array
The Variable in which to store the results of the instruction. When Reps are used the results are stored in
an array with the variable name. An array must be dimensioned to have elements for all the Reps.
Reps
Constant
The number of repetitions for the measurement. For analog measurements, entering reps as a negative
number forces all reps to be on the same channel except for with CR9058E module.
Range
The voltage range for the measurement. V ranges output volts, mV ranges output millivolts.
Constant
± 5 Volt Analog Input
Module
± 50 Volt Analog Input
Module
CR9058E* Isolation Module
Alpha
Code
Num
Code
R *
Option
Code
Voltage
Range
(±mV)
Alpha
Code
Num
Code
R *
Option
Code
Voltage
Range
±
Alpha
Code
Num
Code
R * Option
Code
Voltage Range
mV5000
0
100
5000
V50
6
N/A
50 V
V60
24
N/A
± 60 V
mV1000
1
101
1000
V10
7
N/A
10 V
V20
25
N/A
± 20 V
mV200
4
104
200
V2
10
N/A
2 V
V2
10
N/A
± 2 V
mV50
5
105
50
mV500 11
N/A
500 mV
V2C
22
N/A
± 2 V
mV200C
16
116
200
Alpha Codes ending with a C signify that the channel will be pulled into
See Section
3.2.2 for
more info on
the C & R
range code
options.
mV50C
17
117
50
common mode range & checked for open input. See Section 3.2 for details.
ASlot
Constant
The number of the slot that holds the Analog Input Module to be used for the measurement.
DiffChan
Constant
The differential channel number on which to make the first measurement. When
Reps
are used,
subsequent measurements will be automatically made on the following differential channels.
TCType
The code for the thermocouple type.
Constant
Alpha Code
Numeric Code
Thermocouple Type
TypeT
0
Copper Constantan
TypeE
1 Chromel
Constantan
TypeK
2 Chromel
Alumel
TypeJ
3 Iron
Constantan
TypeB
4 Platinum
Rhodium
TypeR
5 Platinum
Rhodium
TypeS
6 Platinum
Rhodium
TRef
Variable
The name of the variable that is the reference temperature for the thermocouple measurements.
Содержание CR9000
Страница 6: ...CR9000 Table of Contents iv This is a blank page ...
Страница 22: ...CR9000 Overview OV 16 This is a blank page ...
Страница 26: ...Section 1 Installation 1 4 CR9000 FIGURE 1 1 3 CR9000 Battery Pack ...
Страница 72: ...Section 3 CR9000 Measurement Details 3 28 This is a blank page ...
Страница 88: ...Section 5 Program Declarations 5 6 This is a blank page ...
Страница 217: ...This is a blank page ...