4. Specifications
Number of lighting loops
monitored:
4 runways edge and center lighting loops for a total of 8
lighting loops
Type of lights monitored:
LED (up to 6.6 A), incandescent (up to 20 A)
AC input range:
85 to 264 VAC
Short-term input voltage:
300 VAC
Maximum AC input current:
2 A
AC frequency range:
45 to 65 Hz
Inrush surge current:
< 15 A (typical)
Backup battery:
Maintains power to AeroX Light for a minimum of 4 hours
Operating temperature:
–40 to 85 °C
Clamp on current transducer
calibration:
Software controlled
Communications:
TCP/IP communications with Campbell Aero
MTBF:
> 500 000 h in accordance with IEC 61709 (SN 29500)
Transient protection:
Pluggable, no-fuse, fail-safe surge suppression device
Terminals:
Spring clamp terminal connections
Enclosure:
Lockable poly-fiber
Enclosure dimensions:
46 x 51 x 30 cm (18 x 20 x 12 in)
Weight:
14 kg (30 lb)
Compliance:
All components meet UL, CE, and CSA power safety
requirements