manualshive.com logo in svg
background image

Safety

DANGER — MANY HAZARDS ARE ASSOCIATED WITH INSTALLING, USING, MAINTAINING, AND WORKING ON OR AROUND TRIPODS, TOWERS,

AND ANY ATTACHMENTS TO TRIPODS AND TOWERS SUCH AS SENSORS, CROSSARMS, ENCLOSURES, ANTENNAS, ETC. FAILURE TO PROPERLY

AND COMPLETELY ASSEMBLE, INSTALL, OPERATE, USE, AND MAINTAIN TRIPODS, TOWERS, AND ATTACHMENTS, AND FAILURE TO HEED

WARNINGS, INCREASES THE RISK OF DEATH, ACCIDENT, SERIOUS INJURY, PROPERTY DAMAGE, AND PRODUCT FAILURE. TAKE ALL REASONABLE

PRECAUTIONS TO AVOID THESE HAZARDS. CHECK WITH YOUR ORGANIZATION'S SAFETY COORDINATOR (OR POLICY) FOR PROCEDURES AND

REQUIRED PROTECTIVE EQUIPMENT PRIOR TO PERFORMING ANY WORK.

Use tripods, towers, and attachments to tripods and towers only for purposes for which they are designed. Do not exceed design limits. Be familiar

and comply with all instructions provided in product manuals. Manuals are available at www.campbellsci.com. You are responsible for conformance

with governing codes and regulations, including safety regulations, and the integrity and location of structures or land to which towers, tripods, and

any attachments are attached. Installation sites should be evaluated and approved by a qualified engineer. If questions or concerns arise regarding

installation, use, or maintenance of tripods, towers, attachments, or electrical connections, consult with a licensed and qualified engineer or

electrician.

General

l

Protect from over-voltage.

l

Protect electrical equipment from water.

l

Protect from electrostatic discharge (ESD).

l

Protect from lightning.

l

Prior to performing site or installation work, obtain required approvals and permits. Comply with all governing structure-height regulations.

l

Use only qualified personnel for installation, use, and maintenance of tripods and towers, and any attachments to tripods and towers. The

use of licensed and qualified contractors is highly recommended.

l

Read all applicable instructions carefully and understand procedures thoroughly before beginning work.

l

Wear a hardhat and eye protection, and take other appropriate safety precautions while working on or around tripods and towers.

l

Do not climb tripods or towers at any time, and prohibit climbing by other persons. Take reasonable precautions to secure tripod and tower

sites from trespassers.

l

Use only manufacturer recommended parts, materials, and tools.

Utility and Electrical

l

You can be killed or sustain serious bodily injury if the tripod, tower, or attachments you are installing, constructing, using, or maintaining, or

a tool, stake, or anchor, come in contact with overhead or underground utility lines.

l

Maintain a distance of at least one-and-one-half times structure height, 6 meters (20 feet), or the distance required by applicable law,

whichever is greater, between overhead utility lines and the structure (tripod, tower, attachments, or tools).

l

Prior to performing site or installation work, inform all utility companies and have all underground utilities marked.

l

Comply with all electrical codes. Electrical equipment and related grounding devices should be installed by a licensed and qualified

electrician.

l

Only use power sources approved for use in the country of installation to power Campbell Scientific devices.

Elevated Work and Weather

l

Exercise extreme caution when performing elevated work.

l

Use appropriate equipment and safety practices.

l

During installation and maintenance, keep tower and tripod sites clear of un-trained or non-essential personnel. Take precautions to prevent

elevated tools and objects from dropping.

l

Do not perform any work in inclement weather, including wind, rain, snow, lightning, etc.

Maintenance

l

Periodically (at least yearly) check for wear and damage, including corrosion, stress cracks, frayed cables, loose cable clamps, cable tightness,

etc. and take necessary corrective actions.

l

Periodically (at least yearly) check electrical ground connections.

Internal Battery

l

Be aware of fire, explosion, and severe-burn hazards.

l

Misuse or improper installation of the internal lithium battery can cause severe injury.

l

Do not recharge, disassemble, heat above 100 °C (212 °F), solder directly to the cell, incinerate, or expose contents to water. Dispose of spent

batteries properly.

WHILE EVERY ATTEMPT IS MADE TO EMBODY THE HIGHEST DEGREE OF SAFETY IN ALL CAMPBELL SCIENTIFIC PRODUCTS, THE CUSTOMER

ASSUMES ALL RISK FROM ANY INJURY RESULTING FROM IMPROPER INSTALLATION, USE, OR MAINTENANCE OF TRIPODS, TOWERS, OR

ATTACHMENTS TO TRIPODS AND TOWERS SUCH AS SENSORS, CROSSARMS, ENCLOSURES, ANTENNAS, ETC.

Содержание AeroX Light

Страница 1: ...Revision 04 2023 Copyright 2023 Campbell Scientific Inc AeroX Light Runway Light Intensity Monitor RLIM PRODUCT MANUAL...

Страница 2: ...cs 4 5 Configuration 6 5 1 Power configuration 6 5 2 Hardware configuration 6 5 3 Data logger configuration 9 5 3 1 Disable unused services 10 5 3 2 Edit configuration settings 12 5 4 Current transduc...

Страница 3: ...ighting loop using clamp on current transducers Each current transducer outputs from 4 to 20 mA of current proportional to the amount of current in the lighting loop Typically each airport runway has...

Страница 4: ...this manual l Although the AeroX Light is rugged it should be handled as a precision scientific instrument 3 Initial inspection l Upon receipt of the AeroX Light inspect the packaging and contents fo...

Страница 5: ...aintains power to AeroX Light for a minimum of 4 hours Operating temperature 40 to 85 C Clamp on current transducer calibration Software controlled Communications TCP IP communications with Campbell A...

Страница 6: ...4 Schematics AeroX Light 4...

Страница 7: ...AeroX Light 5...

Страница 8: ...circuit voltage of the power supply to 18Vdc 5 2 Hardware configuration One AeroX Light can manage four runways that have two lighting loops per runway When the airport has more than four runways add...

Страница 9: ...H1 9 6 3 6 6 6 Black Red Shield none 1 Center S2 H2 9 6 3 5 5 5 Black Red Shield none 2 Edge S3 H3 9 6 3 4 4 4 Black Red Shield none 2 Center S4 H4 10 7 4 6 6 6 Black Red Shield none 3 Edge S5 H5 10 7...

Страница 10: ...g a jumper to set the current range see Figure 5 2 p 8 and Figure 5 3 p 9 The current transducers are set to the 0 to 10 A scale for the 6 6 A LEDs and to the 0 to 20 A scale for the incandescent ligh...

Страница 11: ...e has constants and variables that are set to identify the hardware configuration that matches the runway and sensor configuration The Public Table contains variables that may need to be changed to ma...

Страница 12: ...typical of incandescent light loops Battery Backup 0 or 1 Battery option installed 0 No 1 Yes NOTE The default time allowed for configuration and calibration is one minute If more time is needed chang...

Страница 13: ...Config Port Used setting is Inactive 8 Click the GOES tab and ensure that the GOES Enabled box is not checked 9 Click the Network Services tab and ensure that none of the boxes are checked 10 Click A...

Страница 14: ...nnected after the data is saved and the data logger restarts The new values are automatically updated in the RLIMCalValues constant table and can be restored to the data logger using the Backup and re...

Страница 15: ...rated and press Enter 5 Type the measured Off light level meter reading value in amps in the Low_Current_ Measurement variable and press Enter NOTE Meter reading must be greater than 0 00 Therefore en...

Страница 16: ...CR1000X in the device type window and select the CR1000X Series 4 For Connection Type click Direct Do not check Specify PakBus Address 5 Select Backup Back Up Datalogger to launch the backup function...

Страница 17: ...r using the supplied USB cable 2 Access the Device Configuration Utility software 3 Type CR1000X in the device type window and select the CR1000X Series 4 For Connection Type click Direct Do not check...

Страница 18: ...5 6 RLlM to Aero communication flow AeroX Light 16...

Страница 19: ...ther manufacturer s products that are resold by Campbell Scientific are warranted only to the limits extended by the original manufacturer Refer to www campbellsci com terms warranty for more informat...

Страница 20: ...ion or Repair Reference number contact your CAMPBELL SCIENTIFIC regional office Please write the issued number clearly on the outside of the shipping container and ship as directed For all returns the...

Страница 21: ...rohibit climbing by other persons Take reasonable precautions to secure tripod and tower sites from trespassers l Use only manufacturer recommended parts materials and tools Utility and Electrical l Y...

Страница 22: ...nfo campbellsci fr www campbellsci fr Germany Location Phone Email Website Bremen Germany 49 0 421 460974 0 info campbellsci de www campbellsci de India Location Phone Email Website New Delhi DL India...

Отзывы: