Table 5-2: Public table variables and values descriptions
Variable
Values
Note
Program_Name
CSIRLIMmsg Do not change
Station_ID
1 (default)
Use the default value of 1 unless multiple RLIM systems
at the airport.
Configuration_Version
V0.0
Changes made to the configuration require
incrementing sCfgVersion
Firmware_Version
V0.0
Factory released version of the CSIRLIMmsg program
Number_RLIMS
1
Number of RLIMS in use at this airport
Number_Runways
1 to 4
RLIM support 1 to 4 runways. Indicate the number of
runways at the airport. Assumption is that each runway
will have an edge and a center lighting loop.
Current_Scale
6.6 or 20
6.6 A is typical of LED light loop; 20 A is typical of
incandescent light loops.
Battery Backup
0 or 1
Battery option installed:
0 = No
1= Yes
NOTE:
The default time allowed for configuration and calibration is one minute. If more time is
needed, change the EntryDelay_Seconds parameter. Double click in the window and change
60 to the desire timeout period. Time displayed in this setting is in seconds.
5.3.1 Disable unused services
Secure the data logger by disabling unused services:
1. Supply power to the data logger by conn12 VDC to the Power In terminals.
2. Connect the data logger USB port to your computer using the supplied USB cable.
3. Access the
Device Configuration Utility
software.
4. Type CR1000X in the device type window and select the CR1000X Series.
5. Select the Connection Type, Communication Port, and Baud Rate, then click Connect.
6. Click the CS I/O IP tab and uncheck the Enabled boxes.
AeroX Light
10