Operating Instructions

www.chpower.com

General Safety Information 

(Continued) 

17. When spraying or cleaning with 

solvents or toxic chemicals, follow 
the instructions provided by the 
chemical manufacturer.

assembly

HanDlE aSSEMBlY 

(Figure 1)

Screws

Washers

Lock Nuts

figure 1 - Handle assembly

1.   Place ends of handle around tank, 

behind the mounting plate. Align 
holes in handle to holes in mounting 
plate.

2.   Assemble four (4) screws and 

washers (from parts package) 
through holes in mounting plate 
and handle. Secure with lock nuts.

 

Never use the   

 handle to lift the 

unit completely off the ground. Only 
use the handle to lift one end so the 
wheels may be used to move the unit.

WHEEl aSSEMBlY 

(Figure 2)

 

Wheel

Nuts

Lock washer

Screws

figure 2 - Wheel assembly

Wheel assembly kit includes:
- 2 wheels*
- 2 axle bolts*
- 2 lock washers*
- 2 nuts*
The items marked with an asterisk (*)
were shipped loose with the unit.
1.   Wheel has an offset hub. With offset 

hub facing axle iron, assemble axle 
bolt through holes in wheel and axle 
iron. 

Since the air compressor and other 
components (filters, lubricators, hoses, 
etc.) used, make up a high pressure 
pumping system, the following safety 
precautions must be observed at all 
times:
1.   Read all manuals included 

with this product carefully. 
Be thoroughly familiar 
with the controls and the 
proper use of the equipment.

2.   Follow all local electrical and 

safety codes as well as in the US, 
National Electrical Code (NEC) and 
Occupational Safety and Health Act 
(OSHA).

3.   Only persons well acquainted with 

these rules of safe operation should 
be allowed to use the compressor.

4.   Keep visitors away and NEVER allow 

children in the work area.

5.   Wear safety glasses and 

use hearing protection 
when operating the pump 
or unit.

6.   Do not stand on or use the pump or 

unit as a handhold.

7.   Before each use, inspect compressed 

air system and electrical components 
for signs of damage, deterioration, 
weakness or leakage. Repair or 
replace defective items before using.

8.   Check all fasteners at frequent 

intervals for proper tightness.

 

Motors, 

 electrical 

equipment and controls can 
cause electrical arcs that will 
ignite a flammable gas or 
vapor. Never operate or repair the unit 
near a flammable gas or vapor. Never 
store flammable liquids or gases in the 
vicinity of the compressor. 
 

Com-   

 pressor 

parts may be hot even if the 
unit is stopped.

9.   Keep fingers away from 

a running compressor; fast moving 
and hot parts will cause injury and/
or burns.

10. If the equipment should start 

to abnormally vibrate, STOP 
the engine/motor and check 
immediately for the cause. Vibration 
is generally a warning of trouble.

11. To reduce fire hazard, 

keep engine/motor 
exterior free of oil, 
solvent, or grease.

 

Never remove or  

 attempt to adjust 

safety valve. Keep safety valve free 
from paint and other accumulations.
 

Never   

 attempt 

to repair or modify a tank! 
Welding, drilling or any other 
modification will weaken the 
tank resulting in damage from rupture 
or explosion. Always replace worn or 
damaged tanks.
 

Drain liquid from  

 tank daily.

12. Tanks rust from moisture build-up, 

which weakens the tank. Make 
sure to drain tank daily and inspect 
periodically for unsafe conditions 
such as rust formation and corrosion.

13. Fast moving air will stir up dust 

and debris which may be harmful. 
Release air slowly when draining 
moisture or depressurizing the 
compressor system.

SpraYInG prECaUtIonS

 

Do not spray 

 flammable 

materials in vicinity of open flame or 
near ignition sources including the 
compressor unit.

14. Do not smoke when spraying paint, 

insecticides, or other flammable 
substances.

15. Use a face mask/ 

respirator when spraying 
and spray in a well 
ventilated area to prevent 
health and fire hazards.

16. Do not direct paint or other sprayed 

material at the compressor. Locate 
compressor as far away from 
the spraying area as possible to 
minimize overspray accumulation on 
the compressor.

MANUAL

Содержание HX5100

Страница 1: ...azardous situation which if not avoided WILL result in death or serious injury Warning indicates a potentially hazardous situation which if not avoided COULD result in death or serious injury Caution...

Страница 2: ...and electrical components for signs of damage deterioration weakness or leakage Repair or replace defective items before using 8 Check all fasteners at frequent intervals for proper tightness Motors e...

Страница 3: ...sk of electrical shock by providing an escape wire for electric current This product is equipped with a cord having a grounding wire with an appropriate grounding plug Plug must be plugged into an out...

Страница 4: ...flow 2 Connect air hose to outlet of regulator 3 Turn on off switch to OFF position 4 Plug in power cord 5 Turn on off switch to AUTO position and let compressor run until it reaches automatic shutof...

Страница 5: ...CHANGE 1 Allow compressor to run and warm up oil Unplug unit 2 Position a pan under pump end of unit 3 Remove oil drain plug see Figure 6 Allow oil to collect in pan Tilt unit to completely drain 4 R...

Страница 6: ...tch 5 Defective motor capacitor 6 Motor shorted or seized 1 Check for proper fuse Use time delay fuse Disconnect other electrical appliances from circuit or operate compressor on its own branch circui...

Страница 7: ...ston and cylinder Excessive moisture in discharge air 1 Excessive water in tank 2 High humidity 1 Drain tank 2 Move to area of less humidity use air line filter Note Water condensation is not caused b...

Страница 8: ...arranty 1 All Compressors a Any component damaged in shipment or any failure caused by installing or operating unit under conditions not in accordance with installation and operation guidelines or dam...

Страница 9: ...ar Informa es gerais N o coloque a unidade em funcionamento caso tenha sido danificada durante o transporte manuseio ou uso O dano pode resultar em ruptura e causar avaria ou dano da estrutura N o dei...

Страница 10: ...te para as m os 7 Antes de cada utiliza o inspecione o sistema de ar comrpimido e os componentes el tricos para verificar sinais de dano deteriora o debilidade ou perdas Conserte ou substitua os itens...

Страница 11: ...el trico por oferecer um cabo el trico para desvio da corrente Este produto est equipado com um cabo contendo um fio de aterramento com seu respectivo conector apropriado Este fio dever ser conectado...

Страница 12: ...abra a v lvula de drenagem O compressor est pronto para o uso Procedimento operacional antes de cada partida 1 Gire o bot o do regulador completamente no sentido anti hor rio para a esquerda para fech...

Страница 13: ...inferior D batidas no tanque para certificar se de que toda umidade foi removida 3 Remova a poeira e a sujeira do tanque linhas de ar e cobertura da bomba enquanto o compressor estiver desligado Troca...

Страница 14: ...to circuito sobrecarregado 2 Fio de espessura errada ou comprimento de cabo de extens o errado 3 V lvula de reten o com defeito 4 V lvula de descarga com defeito no pressostato 5 Condensador do motor...

Страница 15: ...um vazamento for detectado o tanque deve ser substitu do por uma pe a de reposi o original 5 Substitua as v lvulas do compressor conforme necess rio 6 Recoloque o pist o e o cilindro Umidade excessiva...

Страница 16: ...u opera o da unidade sob condi es que n o estejam em conformidade com as diretrizes de instala o e opera o ou danificados devido a contatos com ferramentas ou arredores b Falha da bomba ou v lvula cau...

Страница 17: ...ejo o uso Los da os podr an ocasionar una explosi n y casionarle heridas o da os a su propiedad No lo haga funcionar sin supervisi n El dejar el compresor en la posici n AUTO puede causar que se encie...

Страница 18: ...o 8 Chequ e todas las conexiones frecuentemente para cerciorarse de que est n bien apretadas Los motores equipos el ctricos y controles pueden ocasionar arcos el ctricos que encender an gases o vapore...

Страница 19: ...ar a el riesgo de choque el ctrico al ofrecerle un cable de desv o a la corriente el ctrica Este producto tiene un cord n con un alambre y terminal de conexi n a tierra Debe conectarlo a un tomacorrie...

Страница 20: ...del regulador totalmente hacia la izquierda 2 Conecte la manguera de aire a la salida del regulador 3 Coloque el interruptor de encendido apagado en la posici n OFF apagado 4 Enchufe el cable de corri...

Страница 21: ...s de aire y la cubierta de la bomba mientras el compresor contin a apagado OFF cambios de aceite 1 Encienda el compresor de modo que el aceite se caliente Desenchufe la unidad 2 Coloque un recipiente...

Страница 22: ...correcto circuito sobrecargado 2 Calibre del cable o largo del cord n de extensi n incorrectos 3 V lvula de retenci n defectuosa 4 V lvula de descarga defectuosa en el interruptor de presi n 5 Condens...

Страница 23: ...Si detecta una fuga se deber reemplazar el tanque con una pieza de repuesto original 5 Reemplace las v lvulas del compresor seg n sea necesario 6 Reemplace el pist n y el cilindro Exceso de humedad e...

Страница 24: ...ado por haber instalado u operado la unidad bajo condiciones contrarias a lo indicado en las instrucciones para instalar u operar la unidad o da os ocasionados por el contacto con herramientas o los a...

Отзывы: