manualshive.com logo in svg
background image

4

Operating Instructions

www.chpower.com

operation

•   

pressure Switch

 - Auto/Off Switch 

(Figure 7) - In the 

aUto

 position, the 

compressor shuts off automatically 
when tank pressure reaches the 
maximum preset pressure. In the 

off

 position, the compressor will 

not operate. This switch should be in 
the 

off

 position when connecting 

or disconnecting the power cord 
from the electrical outlet or when 
changing air tools.

  

 

figure 7 - auto/off Switch

•   

regulator

 - The regulator controls 

the amount of air pressure released 
at the hose outlet.

•   

aSME Safety Valve

 - This valve 

automatically releases air if the 
tank pressure exceeds the preset 
maximum.

•   

Exhaust tube 

- This tube carries 

compressed air from the pump to 
the check valve. This tube becomes 
very hot during use. To avoid the 
risk of severe burns, never touch the 
exhaust tube.

•   

Check Valve 

- A one-way valve 

that allows air to enter the tank, 
but prevents air in the tank from 
flowing back into the compressor 
pump.

•   

Handle

 - Designed to move the 

compressor.

 

Never use the   

 handle on wheeled 

units to lift the unit completely off the 
ground.

•   

Drain Valve

 - This valve is located 

on the bottom of the tank. Use 
this valve to drain moisture from 
the tank daily to reduce the risk of 
corrosion.

Reduce tank pressure below 10 psi, then 
drain moisture from tank daily to avoid 
tank corrosion. Drain moisture from 
tank by opening the drain valve located 
underneath the tank.

BEforE fIrSt Start-Up 
BrEaK-In proCEDUrE

(Complete this procedure before using 
compressor for the first time. Once 
completed, it is not necessary to repeat.)
1.   Turn regulator knob fully clockwise 

(to the right) to open air flow.

2.   Turn on/off switch to OFF position.
3.   Plug in power cord.
4.   Turn on/off switch to AUTO position 

and run compressor for 30 minutes.

5.   Turn on/off switch to OFF position.
6.   Unplug power cord- open drain 

valve.

The compressor is now ready for use.

BEforE fIrSt Start-Up 
opEratInG proCEDUrE

1.   Turn regulator knob fully counter 

clockwise (to the left) to close air 
flow.

2.   Connect air hose to outlet of 

regulator.

3.   Turn on/off switch to OFF position.
4.   Plug in power cord.
5.   Turn on/off switch to AUTO position 

and let compressor run until it 
reaches automatic shutoff pressure.

6.   Attach tire chuck or tool to end of 

hose.

7.   Turn regulator knob clockwise (to 

the right) to desired pressure of tool 
being used.

on/off cycling of compressor

In the AUTO position, the compressor 
pumps air into the tank. When a shutoff 
(preset “cut-out”) pressure is reached, 
the compressor automatically shuts off.
If the compressor is left in the AUTO 
position and air is depleted from 
the tank by use of a tire chuck, tool, 
etc., the compressor will restart 
automatically at its preset “cut-in” 
pressure. When a tool is being used 
continuously, the compressor will cycle 
on and off automatically.
In the OFF position, the pressure switch 
cannot function and the compressor 
will not operate. Make sure switch 
is in OFF position when connecting 
or disconnecting power cord from 
electrical outlet.

aSME SafEtY ValVE

 

Do not remove or 

 attempt to adjust 

the safety valve!

Check the safety valve by performing 
the following steps:
1.   Plug the compressor in and run until 

shut off pressure is reached (see 
Operating Procedure).

2.   Wearing safety glasses, pull the 

ring on the safety valve (see Figures 
6 and 8) to release pressure from 
compressor tank. Use your other 
hand to deflect fast-moving air from 
being directed toward your face.

figure 8

MoIStUrE In CoMprESSED aIr

Moisture in compressed air will form into droplets as it comes from an air 
compressor pump. When humidity is high or when a compressor is in continuous 
use for an extended period of time, this moisture will collect in the tank. When 
using a paint spray or sandblast gun, this water will be carried from the tank 
through the hose, and out of the gun as droplets mixed with the spray material.

IMportant: 

This condensation will cause water spots in a paint job, especially 

when spraying other than water based paints. If sandblasting, it will cause 
the sand to cake and clog the gun, rendering it ineffective. A filter in the air 
line (MP3105), located as near to the gun as possible, will help eliminate this 
moisture.

Содержание HX5100

Страница 1: ...azardous situation which if not avoided WILL result in death or serious injury Warning indicates a potentially hazardous situation which if not avoided COULD result in death or serious injury Caution...

Страница 2: ...and electrical components for signs of damage deterioration weakness or leakage Repair or replace defective items before using 8 Check all fasteners at frequent intervals for proper tightness Motors e...

Страница 3: ...sk of electrical shock by providing an escape wire for electric current This product is equipped with a cord having a grounding wire with an appropriate grounding plug Plug must be plugged into an out...

Страница 4: ...flow 2 Connect air hose to outlet of regulator 3 Turn on off switch to OFF position 4 Plug in power cord 5 Turn on off switch to AUTO position and let compressor run until it reaches automatic shutof...

Страница 5: ...CHANGE 1 Allow compressor to run and warm up oil Unplug unit 2 Position a pan under pump end of unit 3 Remove oil drain plug see Figure 6 Allow oil to collect in pan Tilt unit to completely drain 4 R...

Страница 6: ...tch 5 Defective motor capacitor 6 Motor shorted or seized 1 Check for proper fuse Use time delay fuse Disconnect other electrical appliances from circuit or operate compressor on its own branch circui...

Страница 7: ...ston and cylinder Excessive moisture in discharge air 1 Excessive water in tank 2 High humidity 1 Drain tank 2 Move to area of less humidity use air line filter Note Water condensation is not caused b...

Страница 8: ...arranty 1 All Compressors a Any component damaged in shipment or any failure caused by installing or operating unit under conditions not in accordance with installation and operation guidelines or dam...

Страница 9: ...ar Informa es gerais N o coloque a unidade em funcionamento caso tenha sido danificada durante o transporte manuseio ou uso O dano pode resultar em ruptura e causar avaria ou dano da estrutura N o dei...

Страница 10: ...te para as m os 7 Antes de cada utiliza o inspecione o sistema de ar comrpimido e os componentes el tricos para verificar sinais de dano deteriora o debilidade ou perdas Conserte ou substitua os itens...

Страница 11: ...el trico por oferecer um cabo el trico para desvio da corrente Este produto est equipado com um cabo contendo um fio de aterramento com seu respectivo conector apropriado Este fio dever ser conectado...

Страница 12: ...abra a v lvula de drenagem O compressor est pronto para o uso Procedimento operacional antes de cada partida 1 Gire o bot o do regulador completamente no sentido anti hor rio para a esquerda para fech...

Страница 13: ...inferior D batidas no tanque para certificar se de que toda umidade foi removida 3 Remova a poeira e a sujeira do tanque linhas de ar e cobertura da bomba enquanto o compressor estiver desligado Troca...

Страница 14: ...to circuito sobrecarregado 2 Fio de espessura errada ou comprimento de cabo de extens o errado 3 V lvula de reten o com defeito 4 V lvula de descarga com defeito no pressostato 5 Condensador do motor...

Страница 15: ...um vazamento for detectado o tanque deve ser substitu do por uma pe a de reposi o original 5 Substitua as v lvulas do compressor conforme necess rio 6 Recoloque o pist o e o cilindro Umidade excessiva...

Страница 16: ...u opera o da unidade sob condi es que n o estejam em conformidade com as diretrizes de instala o e opera o ou danificados devido a contatos com ferramentas ou arredores b Falha da bomba ou v lvula cau...

Страница 17: ...ejo o uso Los da os podr an ocasionar una explosi n y casionarle heridas o da os a su propiedad No lo haga funcionar sin supervisi n El dejar el compresor en la posici n AUTO puede causar que se encie...

Страница 18: ...o 8 Chequ e todas las conexiones frecuentemente para cerciorarse de que est n bien apretadas Los motores equipos el ctricos y controles pueden ocasionar arcos el ctricos que encender an gases o vapore...

Страница 19: ...ar a el riesgo de choque el ctrico al ofrecerle un cable de desv o a la corriente el ctrica Este producto tiene un cord n con un alambre y terminal de conexi n a tierra Debe conectarlo a un tomacorrie...

Страница 20: ...del regulador totalmente hacia la izquierda 2 Conecte la manguera de aire a la salida del regulador 3 Coloque el interruptor de encendido apagado en la posici n OFF apagado 4 Enchufe el cable de corri...

Страница 21: ...s de aire y la cubierta de la bomba mientras el compresor contin a apagado OFF cambios de aceite 1 Encienda el compresor de modo que el aceite se caliente Desenchufe la unidad 2 Coloque un recipiente...

Страница 22: ...correcto circuito sobrecargado 2 Calibre del cable o largo del cord n de extensi n incorrectos 3 V lvula de retenci n defectuosa 4 V lvula de descarga defectuosa en el interruptor de presi n 5 Condens...

Страница 23: ...Si detecta una fuga se deber reemplazar el tanque con una pieza de repuesto original 5 Reemplace las v lvulas del compresor seg n sea necesario 6 Reemplace el pist n y el cilindro Exceso de humedad e...

Страница 24: ...ado por haber instalado u operado la unidad bajo condiciones contrarias a lo indicado en las instrucciones para instalar u operar la unidad o da os ocasionados por el contacto con herramientas o los a...

Отзывы: