manualshive.com logo in svg
background image

DC0300, FP2090, FP2091, FP2094 Series

5

Operating Instructions and Parts List

on and off automatically. 

In the 

OFF

 position, the pressure 

switch cannot function and the 
compressor will not operate. Make 
sure switch is in 

OFF

 position when 

connecting or disconnecting power 
cord from electrical outlet.

PRESSURE GAUGES

Gauge attached to regulator indicates 
air pressure going to hose (and any 
tool attached to end of hose).

Gauge attached to pressure switch 
indicates air pressure in tank.

Maintenance

 Disconnect, tag  

 

and lock out power 

source, then release all pressure from 
the system before attempting to 
install, service, relocate or perform 
any maintenance.

 Check compressor often for any visible 
problems and follow maintenance 
procedures each time compressor is 
used.

 

Safety valve must 

 be replaced if it 

cannot be actuated or it leaks air after 
ring is released.

1.  Turn compressor off and release 

pressure from system. (To release 
pressure from system, pull ring 
on ASME safety valve. Deflect 
escaping air by shielding valve with 
one hand as you pull ring with 
other hand.) Pull ring until tank is 
empty.

 

A large amount of 

 fast moving air will 

be released when the safety valve is 
opened with pressure in the 
tank. Wear ANSI approved 
Z87.1 safety glasses.

2.  Drain moisture from 

tank by opening drain 
valve underneath tank. Tilt tank to 
remove all moisture.

3.  Clean dust and dirt from tank, 

air lines and pump cover while 
compressor is still OFF.

ASME SAFETY VALVE

 

Do not remove or  

 attempt to adjust 

the safety valve!

Check the safety valve by performing 
the following steps: 

1.  Plug the compressor in and run 

until shut off pressure is reached. 

2.  Wearing safety glasses, pull the 

ring on the safety valve to release 
pressure from compressor tank. 
Use your other hand to defl ect 
fast-moving air from being 
directed toward your face. 

3.  The safety valve should 

automatically close at 
approximately 40 psi - 50 psi. If 
the safety valve does not allow 
air to be released when you pull 
on the ring, or if it does not close 
automatically, it MUST be replaced.

DRAIN TANK

With compressor shut off and pressure 
released, drain moisture from tank by 
opening drain valve underneath tank.

LUBRICATION.

This is an oilless type compressor 
requiring no lubrication.

MOISTURE IN COMPRESSED AIR

Moisture in compressed air will form 
into droplets as it comes from an air 
compressor pump. When humidity 
is high or when a compressor is in 
continuous use for an extended period 
of time, this moisture will collect in 
the tank. When using a paint spray or 
sandblast gun, this water will be carried 
from the tank through the hose, and 
out of the gun as droplets mixed with 
the spray material.

IMPORTANT:

 This condensation will 

cause water spots in a paint job, 
especially when spraying other than 
water based paints. If sandblasting, it 
will cause the sand to cake and clog the 
gun, rendering it ineffective.

A fi lter in the air line, located as near to 
the gun as possible, will help eliminate 
this moisture.

Figure 5

CLEANING

Turn power OFF and clean dust and 
dirt from pump cover, tank, and air 
lines.

OVERLOAD PROTECTOR

 This 

compressor 

 is equipped with 

a thermal overload protector which 
will shut off motor if it becomes 
overloaded.

If overload protector shuts motor OFF 
frequently, look for the following 
causes.

1. Low 

voltage.

2.  Lack of proper ventilation.

 

If the overload 

 protector is 

actuated, the motor must be allowed 
to cool down for 30 minutes before 
manual resetting. 

END OF OPERATION/STORAGE

1.  Turn ON / OFF switch to the OFF 

position.

2.  Unplug power cord from wall 

outlet and wrap around handle 
area to prevent damage when not 
in use.

3.  Wearing safety glasses drain tank 

of air by pulling the ring on the 
safety valve. Use other hand to 
defl ect fast moving air from being 
directed toward your face.

4.  Drain tank of condensation by 

opening drain valve on bottom 
of tank. Tank pressure should be 
below 10 psi when draining tank.  

5.  Air hose should be disconnected 

from compressor and hung open 
ends down to allow any moisture 
to drain.

6.  Compressor and hose should be 

stored in a cool, dry place.

TECHNICAL SERVICE

For information regarding the 
operation or repair of this product, 
please call 1-800-543-6400.

MAINTENANCE SCHEDULE

 OPERATION

DAILY

WEEKLY

MONTHLY

DRAIN TANK

CHECK SAFETY VALVE

CLEAN UNIT

www.campbellhausfeld.com

Содержание DC0300 Series

Страница 1: ...cancer and birth defects or other reproductive harm Wash hands after handling You can create dust when you cut sand drill or grind materials such as wood paint metal concrete cement or other masonry...

Страница 2: ...ing See compressor specification decal for maximum operating pressure Do not operate with pressure switch or pilot valves set higher than the maximum operating pressure 12 Never attempt to adjust ASME...

Страница 3: ...d a wall is required because objects could obstruct air flow Do not locate the compressor air inlet near steam paint spray sandblast areas or any other source of contamination This debris will damage...

Страница 4: ...al codes affecting your particular area The installation should be made by a qualified electrician If the products must be reconnected for use on different types of circuits the re connection should b...

Страница 5: ...N TANK With compressor shut off and pressure released drain moisture from tank by opening drain valve underneath tank LUBRICATION This is an oilless type compressor requiring no lubrication MOISTURE I...

Страница 6: ...Tighten 2 Check valve leaking 2 Remove check valve Clean or replace 3 Loose connections at fittings tubing etc 3 Check all connections with soap and water solution If a leak is detected 1 tighten or 2...

Страница 7: ...DC0300 FP2090 FP2091 FP2094 Series 7 Operating Instructions and Parts List Notes www campbellhausfeld com...

Страница 8: ...Serial number if any Attn Customer Service Part description and number as shown in parts list 100 Production Drive Harrison OH 45030 U S A Operating Instructions and Parts List DC0300 FP2090 FP2091 FP...

Страница 9: ...rain valve D 1403 1 16 Rubber feet tank FP202828AV 4 17 Tank 1 18 Exhaust tube 1 19 Plastic base 1 20 Power cord strain relief FP209534AV 1 21 Accessories 5 pieces models FP209002 FP209102 FP209402 on...

Страница 10: ...icants and adjustment E Items or service that are normally required to maintain the product e g lubricants filters and gaskets etc F Additional items not covered under this warranty 1 Any component da...

Страница 11: ...tient de l information tr s importante qui est fournie pour la S CURIT et pour VITER LES PROBL MES D QUIPEMENT Rechercher les symboles suivants pour cette information Danger indique une situation dang...

Страница 12: ...est g n ralement une indication d un probl me 11 Pour r duire le risque d incendie garder l ext rieur du moteur libre d huile de solvants et de graisse excessive Une soupape de s ret ASME avec une cl...

Страница 13: ...t doit tre mis la terre La fiche doit tre branch e dans une prise qui est en conformit avec tous les codes et ordonnances locaux en plus d tre install e correctement N ENLEVEZ PAS LA BROCHE DE MISE LA...

Страница 14: ...E PREMIER D MARRAGE PROC DURE DE R DAGE Cette proc dure doit tre termin e avant d utiliser le compresseur pour la premi re fois Ensuite il n est pas n cessaire de la refaire 1 Tourner le bouton du r g...

Страница 15: ...GE Ce mod le sans huile n exige pas de graissage HUMIDIT DANS L AIR COMPRIM L humidit dans l air comprim forme des gouttelettes en arrivant de la pompe du compresseur d air Si l humidit est lev e ou s...

Страница 16: ...r es aux raccords tubes etc 3 V rifier toutes les connexions avec une solution de savon et d eau S il y a une fuite 1 resserrer ou 2 retirer le raccord et appliquer du ruban tuyau pour les filets et r...

Страница 17: ...17 Fr Instructions d Utilisation et Manual de Pi ces Notes S rie DC0300 FP2090 FP2091 FP2094...

Страница 18: ...ivante Adresser toute correspondance Num ro de Mod le Campbell Hausfeld Num ro de s rie si pr sent Attn Customer Service Description et num ro de la pi ce 100 Production Drive Harrison OH 45030 U S A...

Страница 19: ...eds en caoutchouc r servoir FP202828AV 4 17 R servoir 1 18 Tube d chappement 1 19 Base de plastique 1 20 Cordon d alimentation Soulagement de tension FP209534AV 1 21 Accessoires 5 pi ces mod les FP209...

Страница 20: ...joints d tanch it s par exemples F Articles suppl mentaires qui ne sont pas couverts sous cette garantie 1 Toutes pi ces d tach es endommag es pendant l exp dition n importe quelle panne caus e par un...

Страница 21: ...idas de Seguridad Este manual contiene informaci n que es muy importante que sepa y comprenda Esta informaci n se la suministramos como medida de SEGURIDAD y para EVITAR PROBLEMAS CON EL EQUIPO Debe r...

Страница 22: ...nte APAGUE la unidad y chequ ela inmediatamente para determinar el problema Generalmente la vibraci n se debe a una falla 11 Para reducir el peligro de incendios mantenga el exterior del compresor lim...

Страница 23: ...on todos los c digos y reglamentos locales y que est instalado correcta mente NO ELIMINE LA PATILLA DE CONEXI N A TIERRA DEL CABLE DE EXTENSI N No coloque la entrada de aire del compresor cerca de rea...

Страница 24: ...ncionamiento ANTES DE ARRANCARLO POR PRIMERA VEZ PROCEDIMIENTO DE ABLANDE Complete este procedimiento antes de usar el compresor por primera vez Una vez completado no es necesario repetirlo 1 Gire la...

Страница 25: ...ndo tira del anillo o si no se cierra autom ticamente DEBE ser reemplazada DRENAJE DEL TANQUE Apague el compresor y libere toda la presi n despu s Abra la llave de drenaje ubicada debajo del tanque pa...

Страница 26: ...la v lvula de retenci n 2 Retire la v lvula de retenci n Limpie o reemplace 3 Conexiones flojas en los accesorios tuber a etc 3 Revise todas las conexiones con una soluci n de agua y jab n Si detecta...

Страница 27: ...27 Sp Manual de Instrucciones de Operaci n y Lista de Piezas Notas Serie DC0300 FP2090 FP2091 FP2094...

Страница 28: ...informaci n Dirija toda la correspondencia a N mero del modelo Campbell Hausfeld C digo impreso Attn Customer Service Descripci n y n mero del repuesto seg n la lista 100 Production Drive de repuesto...

Страница 29: ...ula de drenaje D 1403 1 16 Patas de caucho tanque FP202828AV 4 17 Tanque 1 18 Tubo de escape 1 19 Base de pl stico 1 20 Cord n el ctrico Relevo de tensi n FP209534AV 1 21 Accesorios 5 piezas solo mode...

Страница 30: ...cionales no cubiertos bajo esta garant a 1 Cualquier componente da ado durante el env o o cualquier da o ocasionado por haber instalado u operado la unidad bajo condiciones contrarias a lo indicado en...

Страница 31: ...Notes Notas 31 Operating Instructions and Parts List Instructions d Utilisation et Manual de Pi ces Manual de Instrucciones de Operaci n y Lista de Piezas DC0300 FP2090 FP2091 FP2094...

Страница 32: ...Notes Notas Operating Instructions and Parts List Instructions d Utilisation et Manual de Pi ces Manual de Instrucciones de Operaci n y Lista de Piezas 32 DC0300 FP2090 FP2091 FP2094...

Отзывы: