DC0300, FP2090, FP2091, FP2094 Series

3

Operating Instructions and Parts List

Pressure Switch (located 
internally)- 

When the compressor 

is turned ON, this switch will shut 
compressor off automatically when 
tank pressure reaches maximum shut-
off / cut-out pressure. If compressor 
remains on and air is depleted from 
tank, this switch will allow compressor 
to automatically restart at the restart / 
cut-in pressure.

 Introduction (Continued) 

Regulator - 

The regulator controls 

the amount of air pressure released at 
the hose outlet. Turning the regulator 
knob clockwise (to the right) will 
increase air pressure at the outlet. 
Turning the knob counter-clockwise 
(to the left) will lower air pressure to 
the outlet. Turning knob fully counter-
clockwise will shut off flow of air 
completely.

Pressure Gauges - 

There are two 

gauges located next to the regulator. 
These gauges read air pressure in 
pounds per square inch (psi) The larger 
gauge shows pressure at the outlet. 
Make sure this gauge reads ZERO 
(by adjusting the regulator) BEFORE 
changing air tools or disconnecting 
hose from outlet. The small gauge 
shows pressure in the tank indicating 
compressor is building pressure 
properly. 

to cool down for approximately 30 
minutes before it will reset.

Installation

LOCATION

It is extremely important to use the 
compressor in a clean, well ventilated 
area where the surrounding air 
temperature will not be more than 
100°F.

A minimum clearance of 18 inches 
between the compressor and a wall 
is required because objects could 
obstruct air flow.

 

Do not locate the 

 compressor 

air inlet near steam, paint spray, 
sandblast areas or any other source 
of contamination. This debris will 
damage the motor.

GROUNDING INSTRUCTIONS

1. This product is for use on a nominal 

120 v circuit. It must be grounded. In 
the event of an electric short circuit, 
grounding reduces the risk of 
electrical shock by providing an 
escape wire for the electric current. 
Unit is equipped with a cord that 
has a grounding prong. It will fit 
one of the common outlet types 
shown in Figure 7. If plug will not fit 
in the desired outlet, have the plug 
or the outlet replaced by a qualified 
electrician.

ASME Safety Valve - 

This valve 

automatically releases air if the tank 
pressure exceeds the preset maximum.

Handle - 

Designed to move the 

compressor.

Drain Valve - 

This valve is located on 

the bottom of the tank. Use this valve 
to drain moisture from the tank daily 
to reduce the risk of corrosion.

Motor Reset

 - (not shown, located 

inside motor). Designed to keep the 
motor from overheating. The motor 
has a self-hold protector. If the unit 
is over worked, a thermal limiter will 
shut unit off. If it happens, switch the 
unit to the OFF position and unplug 
the unit. Wait 30 minutes, plug the 
unit in and switch the unit to the 
ON position again to resume work.

 

This compressor is 

 equipped with an 

overload protector which will shut off 
motor if it becomes overloaded.

 

If the overload 

 protector is 

actuated, the motor must be allowed 

Figure 2

Figure 3

Tank Drain Valve

ASME Safety Valve

Tank

Handle

Shroud

Regulator

Tank Gauge

Regulator Gauge

ON / OFF Switch

Air Outlet

www.campbellhausfeld.com

Содержание DC0300 Series

Страница 1: ...cancer and birth defects or other reproductive harm Wash hands after handling You can create dust when you cut sand drill or grind materials such as wood paint metal concrete cement or other masonry...

Страница 2: ...ing See compressor specification decal for maximum operating pressure Do not operate with pressure switch or pilot valves set higher than the maximum operating pressure 12 Never attempt to adjust ASME...

Страница 3: ...d a wall is required because objects could obstruct air flow Do not locate the compressor air inlet near steam paint spray sandblast areas or any other source of contamination This debris will damage...

Страница 4: ...al codes affecting your particular area The installation should be made by a qualified electrician If the products must be reconnected for use on different types of circuits the re connection should b...

Страница 5: ...N TANK With compressor shut off and pressure released drain moisture from tank by opening drain valve underneath tank LUBRICATION This is an oilless type compressor requiring no lubrication MOISTURE I...

Страница 6: ...Tighten 2 Check valve leaking 2 Remove check valve Clean or replace 3 Loose connections at fittings tubing etc 3 Check all connections with soap and water solution If a leak is detected 1 tighten or 2...

Страница 7: ...DC0300 FP2090 FP2091 FP2094 Series 7 Operating Instructions and Parts List Notes www campbellhausfeld com...

Страница 8: ...Serial number if any Attn Customer Service Part description and number as shown in parts list 100 Production Drive Harrison OH 45030 U S A Operating Instructions and Parts List DC0300 FP2090 FP2091 FP...

Страница 9: ...rain valve D 1403 1 16 Rubber feet tank FP202828AV 4 17 Tank 1 18 Exhaust tube 1 19 Plastic base 1 20 Power cord strain relief FP209534AV 1 21 Accessories 5 pieces models FP209002 FP209102 FP209402 on...

Страница 10: ...icants and adjustment E Items or service that are normally required to maintain the product e g lubricants filters and gaskets etc F Additional items not covered under this warranty 1 Any component da...

Страница 11: ...tient de l information tr s importante qui est fournie pour la S CURIT et pour VITER LES PROBL MES D QUIPEMENT Rechercher les symboles suivants pour cette information Danger indique une situation dang...

Страница 12: ...est g n ralement une indication d un probl me 11 Pour r duire le risque d incendie garder l ext rieur du moteur libre d huile de solvants et de graisse excessive Une soupape de s ret ASME avec une cl...

Страница 13: ...t doit tre mis la terre La fiche doit tre branch e dans une prise qui est en conformit avec tous les codes et ordonnances locaux en plus d tre install e correctement N ENLEVEZ PAS LA BROCHE DE MISE LA...

Страница 14: ...E PREMIER D MARRAGE PROC DURE DE R DAGE Cette proc dure doit tre termin e avant d utiliser le compresseur pour la premi re fois Ensuite il n est pas n cessaire de la refaire 1 Tourner le bouton du r g...

Страница 15: ...GE Ce mod le sans huile n exige pas de graissage HUMIDIT DANS L AIR COMPRIM L humidit dans l air comprim forme des gouttelettes en arrivant de la pompe du compresseur d air Si l humidit est lev e ou s...

Страница 16: ...r es aux raccords tubes etc 3 V rifier toutes les connexions avec une solution de savon et d eau S il y a une fuite 1 resserrer ou 2 retirer le raccord et appliquer du ruban tuyau pour les filets et r...

Страница 17: ...17 Fr Instructions d Utilisation et Manual de Pi ces Notes S rie DC0300 FP2090 FP2091 FP2094...

Страница 18: ...ivante Adresser toute correspondance Num ro de Mod le Campbell Hausfeld Num ro de s rie si pr sent Attn Customer Service Description et num ro de la pi ce 100 Production Drive Harrison OH 45030 U S A...

Страница 19: ...eds en caoutchouc r servoir FP202828AV 4 17 R servoir 1 18 Tube d chappement 1 19 Base de plastique 1 20 Cordon d alimentation Soulagement de tension FP209534AV 1 21 Accessoires 5 pi ces mod les FP209...

Страница 20: ...joints d tanch it s par exemples F Articles suppl mentaires qui ne sont pas couverts sous cette garantie 1 Toutes pi ces d tach es endommag es pendant l exp dition n importe quelle panne caus e par un...

Страница 21: ...idas de Seguridad Este manual contiene informaci n que es muy importante que sepa y comprenda Esta informaci n se la suministramos como medida de SEGURIDAD y para EVITAR PROBLEMAS CON EL EQUIPO Debe r...

Страница 22: ...nte APAGUE la unidad y chequ ela inmediatamente para determinar el problema Generalmente la vibraci n se debe a una falla 11 Para reducir el peligro de incendios mantenga el exterior del compresor lim...

Страница 23: ...on todos los c digos y reglamentos locales y que est instalado correcta mente NO ELIMINE LA PATILLA DE CONEXI N A TIERRA DEL CABLE DE EXTENSI N No coloque la entrada de aire del compresor cerca de rea...

Страница 24: ...ncionamiento ANTES DE ARRANCARLO POR PRIMERA VEZ PROCEDIMIENTO DE ABLANDE Complete este procedimiento antes de usar el compresor por primera vez Una vez completado no es necesario repetirlo 1 Gire la...

Страница 25: ...ndo tira del anillo o si no se cierra autom ticamente DEBE ser reemplazada DRENAJE DEL TANQUE Apague el compresor y libere toda la presi n despu s Abra la llave de drenaje ubicada debajo del tanque pa...

Страница 26: ...la v lvula de retenci n 2 Retire la v lvula de retenci n Limpie o reemplace 3 Conexiones flojas en los accesorios tuber a etc 3 Revise todas las conexiones con una soluci n de agua y jab n Si detecta...

Страница 27: ...27 Sp Manual de Instrucciones de Operaci n y Lista de Piezas Notas Serie DC0300 FP2090 FP2091 FP2094...

Страница 28: ...informaci n Dirija toda la correspondencia a N mero del modelo Campbell Hausfeld C digo impreso Attn Customer Service Descripci n y n mero del repuesto seg n la lista 100 Production Drive de repuesto...

Страница 29: ...ula de drenaje D 1403 1 16 Patas de caucho tanque FP202828AV 4 17 Tanque 1 18 Tubo de escape 1 19 Base de pl stico 1 20 Cord n el ctrico Relevo de tensi n FP209534AV 1 21 Accesorios 5 piezas solo mode...

Страница 30: ...cionales no cubiertos bajo esta garant a 1 Cualquier componente da ado durante el env o o cualquier da o ocasionado por haber instalado u operado la unidad bajo condiciones contrarias a lo indicado en...

Страница 31: ...Notes Notas 31 Operating Instructions and Parts List Instructions d Utilisation et Manual de Pi ces Manual de Instrucciones de Operaci n y Lista de Piezas DC0300 FP2090 FP2091 FP2094...

Страница 32: ...Notes Notas Operating Instructions and Parts List Instructions d Utilisation et Manual de Pi ces Manual de Instrucciones de Operaci n y Lista de Piezas 32 DC0300 FP2090 FP2091 FP2094...

Отзывы: