manualshive.com logo in svg
background image

Operating Instructions and Parts List

4

DC0300, FP2090, FP2091, FP2094 Series

Improper use of grounding plug can result 
in a risk of electrical shock. Plug must be 
plugged into an outlet that is properly 
installed and grounded in accordance with 
local codes and ordinances

NOTE: Do not use grounding adapter.

2. Use only a 3-wire extension cord 

that has a 3-blade grounding 
plug, and a 3-slot receptacle that 
accepts the plug on the product. 
Make sure your extension cord 
is not damaged. When using an 
extension cord, be sure to use 
one heavy enough to carry the 
current your product draws. For 
lengths less than  25ft. 18-3 AWG 
extension cords shall be used. An 
undersized cord results in a drop in 
the voltage and loss of power and 
overheating. (NOTE: Table 1 shows 
the correct size to use depending 
on cord length. When in doubt, 
use the next heavier gauge. The 
smaller the gauge number, the 
heavier the cord.) 

3.   Check with a qualified electrician 

or serviceman if the grounding 
instructions are not completely 
understood, or if in doubt as to 
whether the product is properly 
grounded. Do not modify the 
plug provided; if it will not fit the 
outlet, have the proper outlet 
installed by a qualified electrician.

If repair or 
replacement of 
the cord or plug 

is necessary, do not connect the 
grounding wire to either flat blade 
terminal. The wire with insulation 
having an outer surface that is green 

with or without yellow stripes is the 

grounding wire.

PLUGS AND RECEPTACLES

1.   If the plug on the electrical cord of 

the unit is unfamiliar to you or will 
not fit your particular receptacle, 
Figure 7 will help you understand 
why by illustrating the different 
plugs and the voltages they are to be 
used with.

2.   Make sure that the product is 

connected to an outlet having the 
same configuration as the plug. 

3.   The receptacles must be connected 

to circuits rated to carry at least the 
voltage and amperages shown. 

4.   NEVER have a receptacle replaced 

with one of a higher amperage 
before determining the change can 
be made according to all electrical 
codes affecting your particular area. 
The installation should be made 
by a qualified electrician. If the 
products must be reconnected for 
use on different types of circuits, the 
re-connection should be made by 
qualified personnel.

 Overheating, 

short 

 circuiting and fi re 

damage will result from 
inadequate wiring.

LUBRICATION

This is an oilless product and 

DOES 

NOT

 require lubrication to operate.

Pre-Operation

 

BEFORE FIRST START-UP
BREAK-IN PROCEDURE

(Complete this procedure before 
using compressor for the first time. 
Once completed, it is not necessary to 
repeat.)

1.  Turn regulator knob fully clockwise 

(to the right) to open air fl ow.

2. 

Do not

 attach a hose or any other 

fi tting to the compressor.

3. Turn 

ON / OFF

 switch to 

OFF

 

position.

4.  Plug in power cord.

5. Turn 

ON / OFF

 switch to 

ON

 

position and run compressor for 30 
minutes.

6. Turn 

ON / OFF

 switch to 

OFF

 

position.

7.  Unplug power cord.

The compressor is now ready for use.

BEFORE EACH START-UP
OPERATING PROCEDURE

1.  Turn regulator knob fully 

counterclockwise (to the left) to 
close air fl ow. 

2.  Connect air hose to outlet of 

regulator.

3. Turn 

ON / OFF

 switch to 

OFF

 

position.

4.  Plug in power cord.

5. Turn 

ON / OFF

 switch to 

ON

 

position and let compressor run 
until it reaches automatic shutoff 
pressure.

6.  Attach tire chuck or tool to end of 

hose.

7.  Turn regulator knob clockwise (to 

the right) to desired pressure of 
tool being used.

 

Operation

 START-UP

 

Do not attach air 

 tools to open end 

of the hose until start-up is completed 
and the unit checks OK.

ON / OFF CYCLING OF COMPRESSOR

In the 

ON / AUTO

 position, the 

compressor pumps air into the tank. 
When a shut-off (preset “cut-out”) 
pressure is reached, the compressor 
automatically shuts off.

If the compressor is left in the 

ON / AUTO

 position and air is depleted 

from the tank by use of a tire chuck, 
tool, etc., the compressor will restart 
automatically at its preset “cut-in” 
pressure. When a tool is being used 
continuously, the compressor will cycle 

Ground Pin

Grounded Outlet

Grounded Outlet

Ground Pin

120V
20A

120V
15A

240V
20A

240V
15A

Figure 7

Amp 

Rating 

Range

Voltage

Cord Length in Feet

120V

25 ft

50 ft

100 ft

150 ft

200 ft

250 ft

300 ft

400 ft

500 ft

0-2

18

18

18

16

16

14

14

12

12

Table 1

Do not use 240v

Correct 

www.campbellhausfeld.com

Содержание DC0300 Series

Страница 1: ...cancer and birth defects or other reproductive harm Wash hands after handling You can create dust when you cut sand drill or grind materials such as wood paint metal concrete cement or other masonry...

Страница 2: ...ing See compressor specification decal for maximum operating pressure Do not operate with pressure switch or pilot valves set higher than the maximum operating pressure 12 Never attempt to adjust ASME...

Страница 3: ...d a wall is required because objects could obstruct air flow Do not locate the compressor air inlet near steam paint spray sandblast areas or any other source of contamination This debris will damage...

Страница 4: ...al codes affecting your particular area The installation should be made by a qualified electrician If the products must be reconnected for use on different types of circuits the re connection should b...

Страница 5: ...N TANK With compressor shut off and pressure released drain moisture from tank by opening drain valve underneath tank LUBRICATION This is an oilless type compressor requiring no lubrication MOISTURE I...

Страница 6: ...Tighten 2 Check valve leaking 2 Remove check valve Clean or replace 3 Loose connections at fittings tubing etc 3 Check all connections with soap and water solution If a leak is detected 1 tighten or 2...

Страница 7: ...DC0300 FP2090 FP2091 FP2094 Series 7 Operating Instructions and Parts List Notes www campbellhausfeld com...

Страница 8: ...Serial number if any Attn Customer Service Part description and number as shown in parts list 100 Production Drive Harrison OH 45030 U S A Operating Instructions and Parts List DC0300 FP2090 FP2091 FP...

Страница 9: ...rain valve D 1403 1 16 Rubber feet tank FP202828AV 4 17 Tank 1 18 Exhaust tube 1 19 Plastic base 1 20 Power cord strain relief FP209534AV 1 21 Accessories 5 pieces models FP209002 FP209102 FP209402 on...

Страница 10: ...icants and adjustment E Items or service that are normally required to maintain the product e g lubricants filters and gaskets etc F Additional items not covered under this warranty 1 Any component da...

Страница 11: ...tient de l information tr s importante qui est fournie pour la S CURIT et pour VITER LES PROBL MES D QUIPEMENT Rechercher les symboles suivants pour cette information Danger indique une situation dang...

Страница 12: ...est g n ralement une indication d un probl me 11 Pour r duire le risque d incendie garder l ext rieur du moteur libre d huile de solvants et de graisse excessive Une soupape de s ret ASME avec une cl...

Страница 13: ...t doit tre mis la terre La fiche doit tre branch e dans une prise qui est en conformit avec tous les codes et ordonnances locaux en plus d tre install e correctement N ENLEVEZ PAS LA BROCHE DE MISE LA...

Страница 14: ...E PREMIER D MARRAGE PROC DURE DE R DAGE Cette proc dure doit tre termin e avant d utiliser le compresseur pour la premi re fois Ensuite il n est pas n cessaire de la refaire 1 Tourner le bouton du r g...

Страница 15: ...GE Ce mod le sans huile n exige pas de graissage HUMIDIT DANS L AIR COMPRIM L humidit dans l air comprim forme des gouttelettes en arrivant de la pompe du compresseur d air Si l humidit est lev e ou s...

Страница 16: ...r es aux raccords tubes etc 3 V rifier toutes les connexions avec une solution de savon et d eau S il y a une fuite 1 resserrer ou 2 retirer le raccord et appliquer du ruban tuyau pour les filets et r...

Страница 17: ...17 Fr Instructions d Utilisation et Manual de Pi ces Notes S rie DC0300 FP2090 FP2091 FP2094...

Страница 18: ...ivante Adresser toute correspondance Num ro de Mod le Campbell Hausfeld Num ro de s rie si pr sent Attn Customer Service Description et num ro de la pi ce 100 Production Drive Harrison OH 45030 U S A...

Страница 19: ...eds en caoutchouc r servoir FP202828AV 4 17 R servoir 1 18 Tube d chappement 1 19 Base de plastique 1 20 Cordon d alimentation Soulagement de tension FP209534AV 1 21 Accessoires 5 pi ces mod les FP209...

Страница 20: ...joints d tanch it s par exemples F Articles suppl mentaires qui ne sont pas couverts sous cette garantie 1 Toutes pi ces d tach es endommag es pendant l exp dition n importe quelle panne caus e par un...

Страница 21: ...idas de Seguridad Este manual contiene informaci n que es muy importante que sepa y comprenda Esta informaci n se la suministramos como medida de SEGURIDAD y para EVITAR PROBLEMAS CON EL EQUIPO Debe r...

Страница 22: ...nte APAGUE la unidad y chequ ela inmediatamente para determinar el problema Generalmente la vibraci n se debe a una falla 11 Para reducir el peligro de incendios mantenga el exterior del compresor lim...

Страница 23: ...on todos los c digos y reglamentos locales y que est instalado correcta mente NO ELIMINE LA PATILLA DE CONEXI N A TIERRA DEL CABLE DE EXTENSI N No coloque la entrada de aire del compresor cerca de rea...

Страница 24: ...ncionamiento ANTES DE ARRANCARLO POR PRIMERA VEZ PROCEDIMIENTO DE ABLANDE Complete este procedimiento antes de usar el compresor por primera vez Una vez completado no es necesario repetirlo 1 Gire la...

Страница 25: ...ndo tira del anillo o si no se cierra autom ticamente DEBE ser reemplazada DRENAJE DEL TANQUE Apague el compresor y libere toda la presi n despu s Abra la llave de drenaje ubicada debajo del tanque pa...

Страница 26: ...la v lvula de retenci n 2 Retire la v lvula de retenci n Limpie o reemplace 3 Conexiones flojas en los accesorios tuber a etc 3 Revise todas las conexiones con una soluci n de agua y jab n Si detecta...

Страница 27: ...27 Sp Manual de Instrucciones de Operaci n y Lista de Piezas Notas Serie DC0300 FP2090 FP2091 FP2094...

Страница 28: ...informaci n Dirija toda la correspondencia a N mero del modelo Campbell Hausfeld C digo impreso Attn Customer Service Descripci n y n mero del repuesto seg n la lista 100 Production Drive de repuesto...

Страница 29: ...ula de drenaje D 1403 1 16 Patas de caucho tanque FP202828AV 4 17 Tanque 1 18 Tubo de escape 1 19 Base de pl stico 1 20 Cord n el ctrico Relevo de tensi n FP209534AV 1 21 Accesorios 5 piezas solo mode...

Страница 30: ...cionales no cubiertos bajo esta garant a 1 Cualquier componente da ado durante el env o o cualquier da o ocasionado por haber instalado u operado la unidad bajo condiciones contrarias a lo indicado en...

Страница 31: ...Notes Notas 31 Operating Instructions and Parts List Instructions d Utilisation et Manual de Pi ces Manual de Instrucciones de Operaci n y Lista de Piezas DC0300 FP2090 FP2091 FP2094...

Страница 32: ...Notes Notas Operating Instructions and Parts List Instructions d Utilisation et Manual de Pi ces Manual de Instrucciones de Operaci n y Lista de Piezas 32 DC0300 FP2090 FP2091 FP2094...

Отзывы: