11
AF
ZL150
QUADRO COMANDO
T.L.
T.C.A.
AP.PARZ.
2
1
3
4
5
6
7
8
9
1 0
O N
FUSIBILE
LINEA 5A
FUSIBILE
CENTR. 3.15A
L1T L2T
0
15
24 20
SELEZIONI FUNZIONI -
SELECTION OF FUNCTIONS - SÉLECTION FONCTIONS
FUNKTIONSWAHL - SELECCIÓN DE LAS FUNCIONES
DIP-SWITCH 10 VIE
10-WAY DIP-SWITCH
DIP-SWITCH 10 VOIES
ZEHNWEG-DIP-SWITCH
DIP-SWITCH 10 VÍAS
1 ON
Chiusura automatica attivata; (1OFF-disattivata)
2 ON
"Apre-stop-chiude-stop" con pulsante (2-7) e radio-
comando (scheda AF inserita) attivata;
2 OFF
"Apre-chiude" con pulsante (2-7) e radiocomando
(scheda AF inserita) attivata;
3 ON
"Solo apertura" con radiocomando (scheda AF inserita)
attivata; (3OFF-disattivata)
4 ON
Prelampeggio in apertura e chiusura attivato; (4OFF-
disat.)
5 ON
Rilevazione presenza ostacolo attivato; (5OFFdis.)
6 OFF
"Uomo presente" (esclude il funzionamento del
radiocomando) disattivata; (6ON - attivata)
7 ON
Colpo d'ariete attivato; (per facilitare lo sgancio della
serratura) 7OFF-disattivato
8 OFF - 10 OFF
Funzione di richiusura in fase di apertura
(collegare il dispositivo di sicurezza sui morsetti 2-CX)
attivato;
8 OFF - 10 ON
Funzione di stop parziale (collegare il
dispositivo di sicurezza sui morsetti 2-CX) attivato;
(se non vengono utilizzati i dispositivi su 2-CX, posizionare il dip
8 in ON)
9 OFF
Funzione di riapertura in fase di chiusura attivato; con
dispositivo di sicurezza collegato ai morsetti 2-C1, (se
non viene utilizzato il dispositivo, selezionare il dip in
ON)
ITALIANO
ITALIANO
ITALIANO
ITALIANO
ITALIANO
2
1
3
4
5
6
7
8
9 10
O
N
ON
ON
ON
ON
ON
OFF
OFF
OFF
OFF
OFF
ENGLISH
ENGLISH
ENGLISH
ENGLISH
ENGLISH
1 ON
Automatic closure enabled; (1OFF-disabled)
2 ON
"Open-stop-close-stop" with button (2-7) and radio
control (AF board inserted) enabled;
2 OFF
"Open-close" with button (2-7) and radio control (AF
board inserted) enabled;
3 ON
"Only opening" with radio control (AF board inserted)
enabled; (3OFF-disabled)
4 ON
Pre-flashing (opening and closing) enabled; (4OFF-
disabled)
5 ON
Obstacle detection device enabled; (5OFF - disabled)
6 OFF
"Operator present" (radio remote control is deactivated
when function is selected) disabled; (6ON-enabled)
7 ON
Hammer movement operation enabled; (this function
helps unlock the electric lock) 7OFF-disabled
8OFF - 10 OFF
Re-closure during opening (connect the
safety device on terminals (2-CX) enabled;
8OFF - 10 ON
Partial stop (connect the safety device on
terminals (2-CX) enabled;
(if the devices on the 2-CX terminals are not used, set Dip 8 in
ON)
9 OFF
Re-opening in closing phase (connect the safety device
on terminals 2-C1) enabled; if not used, set the dip-
switch to ON.
FRANÇAIS
FRANÇAIS
FRANÇAIS
FRANÇAIS
FRANÇAIS
1 ON
Fermeture automatique activé; (1OFF-éteinte)
2 ON
"Ouvre-stop-ferme-stop" avec bouton (2-7) et
commande-radio (carte AF insérée) activé;
2 OFF
"Ouvre-ferme" avec bouton (2-7) et commande-radio
(carte AF insérée) activé;
3 ON
"Soulement ouverture" avec commande-radio (carte
AF insérée) activé; (3OFF-éteinte)
4 ON
Preclignotement pandant la phase d'ouverture et de
fermeture activé; (4OFF-éteinte.)
5 ON
Dispositif de détection d'obstacle activé; (5OFF
éteinte)
6 OFF
Fonction avec "homme mort" (exclut la fonction
radiocommande) éteinte; (6ON - activé)
7 ON
Fonction coup de bélier activé; (pour faciliter le
déblocage de la serrure) 7OFF-éteinte
8OFF - 10 OFF
Réfermeture en phase d'ouverture (relier le
dispositif de sécurite aux bornes 2-CX) activé;
8OFF - 10 ON
Stop partiel (relier le dispositif de sécurite aux
bornes 2-CX) activé;
(si le dispositif sur 2-CX ne sont pas utilisés, positionner le dip 8
sur ON)
9 OFF
Réouverture en phase de fermeture activé; relier le
dispositif de sécuritè aux bornes 2-C1; s'il n'est pas
utilisé, positionner l'interrupteur à positions multiples
sur ON.