Description of circuit board

1

RS-485 bus terminals for connecting keypads, radio 

concentrators and readers:

[+,-]   power supply to bus;

[A,B] data;

[F6]  

self-restoring 1 35 A fuse 

2

Terminals for control unit inputs, can be types NA, NC, SB, 

DB, CI:

[+,-] 

 

power supply;

[1,2,3,4,5,6]  

inputs (the reference is at negative);

[F3]  

self-restoring 1 35 A fuse 

3

Terminals for control unit outputs:

[AUX +, -] 

power supply available via self-restoring 

fuse protected output F5;

[U1]  

 

programmable positive output protected 

by 100 ohm resistor (ON=13 8 V DC, OFF=NA);

[U1]  

 

programmable open collector negative 

output protected by 100 ohm resistor (ON=0 V DC, 

OFF=NA);

[NO, C, NC] 

general alarm relay with clean contacts;

[F5]  

self-restoring 1 35 A fuse 

 A short circuit with active open collector output for a 

long time may lead to breakage of the protective resistor 

4

[JP3] 

link to enable/disable the anti-opening tamper 

(position C to disable it, position O to enable it) 

[JP4] 

link to enable/disable the anti-tear tamper 

(position C to disable it, position O to enable it) 

5 [SW2]  Control unit anti-opening sliding tamper 
6 [SW3]  Control unit anti-opening sliding tamper 
7 [CN2] 

connector for GSM module 

[F4]  

self-restoring 1 35 A fuse 

Description of circuit board

POWER DRAWS AND BATTERY LIFE OF PXC99W POWERED BY 

12V DC 2 2Ah BATTERY

Power draw with control unit on 
stand-by with no accessories 
and peripherals connected

• 95mA with keypad backlight-
ing off
• 110mA with keypad back-
lighting on at maximum bright-
ness

Power draw with control unit in 
alarm mode and PSTN on a call

155mA

Description of circuit board

8

 

O

N

1

 

Dip1 is used to move the control unit over from 

service to maintenance (ON= Maintenance, OFF= Service) 

 

O

N

1

 

Dip2 is used to restore the Codes to factory 

settings 

 

O

N

1

 

Dip3 is used to restore the factory settings 

(para codes + keys) 

 

O

N

1

 

Dip4 is used to reprogramme the control unit 

firmware 

9 [P1] 

button to restart the control unit (it is not used to 

restore parameters; it does not alter the settings) 

10

PE] 

terminal for earthing 

[L, L] 

terminals for external PSTN telephone line input 

[T, T] 

terminals for PSTN telephone line output to phone 

or switchboard 

11

[CN1] 

connector for connection to Ethernet interface or 

to the Touch Screen via the PXITS4 3 interface 

[F4]  

self-restoring 1 35 A fuse 

12 [CN9] 

USB socket for connection to PC (with type A-B 

USB cable) 

13 [F8] 

glass T fuse, 3 15 A 

14 [V AC]  terminals for connection to 230V AC power grid 
15 [CN7] 

connector for battery 

[F2]  

self-restoring 1 6 A fuse 

16 [CN13]  connector for connection of the control unit base 

board to the keypad card 

17 [CN3] 

connector for connection of the control unit base 

board to the audio card 

18 Radio signalling LEDs

POWER DRAWS AND BATTERY LIFE OF PXC99W POWERED BY 

12V DC 2 2Ah BATTERY

Power draw with control unit in 
alarm mode and GSM on a call

230mA

Battery life* with control unit on 
stand-by with no accessories 
and peripherals connected

Minimum 15 hours

* WARNING: The battery life is reduced depending on the num-
ber of alarms and/or phone calls and/or manoeuvres carried out, 
and depending on the number of possible accessories/peripherals 
connected

Содержание PXC99W

Страница 1: ...SECURITY ALARM CONTROL UNIT INSTALLER MANUAL PXC99W FA00464 EN...

Страница 2: ...TION 15 ADDRESSING 15 ACCESSORIES PAG 16 PXGSM 16 CIRCUIT BOARD DESCRIPTION 16 INSTALLATION 16 PXLAN PXWEB LAN INTERFACES 16 CIRCUIT BOARD DESCRIPTION 16 INSTALLATION 16 PXKNX 17 CIRCUIT BOARD DESCRIP...

Страница 3: ...ary power supply and the relative connections to earth Once the system is up and running make sure the User has changed the factory User Code 123456 STANDARD EN 50131 SPECIFIC RECOMMENDATIONS To ensur...

Страница 4: ...ephone Tablet Modem Router Switch Local PC PXDGETH LAN dongle 1 Building automation system CAME Domotic 3 0 PXIPC01 Programming cable LAN network INTERNET RS485 bus PSTN line Internal connection Stand...

Страница 5: ...and twisted pair cable with a cross section of at least 2 x 0 5 mm for power supply and twisted pair 2 x 0 22 mm for data 2 x 0 5 mm for power supply and twisted pair 2 x 2 x 0 22 mm for data used to...

Страница 6: ...A and B Analysing the circuit made in this way you can see that the structure of the RS 485 bus is still linear entry exit DOUBLE BRANCH CABLING RS 485 CABLE Screened 2 x 1 5 mm twisted 2 x 0 22 mm C...

Страница 7: ...4 EN ver 1 03 2017 CAME S p a The data and information shown in this manual are to be considered as subject to change at any time and without the need for any advance warning CABLING WITH BUS AMPLIFIE...

Страница 8: ...II Insulation class Dimensions HxWxD mm 300x250x65 Case ABS RAL9003 IP Rating IP30 Weight kg 2 70 Scenarios 16 Radio inputs 99 Wired inputs in control unit 6 Type of inputs in control unit NC NA SB D...

Страница 9: ...eripherals connected 95mA with keypad backlight ing off 110mA with keypad back lighting on at maximum bright ness Power draw with control unit in alarm mode and PSTN on a call 155mA Description of cir...

Страница 10: ...f The output is protected by a 100 ohm resistor It can also be used to control sirens or other loads U2 U3 U4 PROGRAMMABLE OUTPUT Open Collector A short circuit at 12V CC with active output for a long...

Страница 11: ...s a general alarm output and is not programmable It follows the general alarm status and remains active for the programmed time Non self powered siren Self powered siren PSTN TELEPHONE LINE The PSTN t...

Страница 12: ...6 7 8 Areas partially on 9 Areas not ready 10 Areas off 10 11 12 13 DISPLAY ICONS Symbol Meaning CAME logo System armed System disarmed System partially armed Programming Events memory User menu or re...

Страница 13: ...d disabled Symbol Meaning Alarm memory Not ready for arming Generic power supply failure 230 V network power supply failure Battery failure PSTN line down GSM line down Serial connection local Etherne...

Страница 14: ...the keypad software version to be viewed Pressing twice in succession takes you out of the Keypad Menu If xx seconds pass without any action the keypad goes into STAND BY mode and after a further xx...

Страница 15: ...system man agement off constantly on flashing on rapidly slowly With the transponder reader you can view the system status through the signals provided by its LEDs as in the previous table Depending u...

Страница 16: ...ge For remote connection to the PXLAN and PXWEB interfaces the router connected to your home network must be configured see the relative instruction manual CIRCUIT BOARD DESCRIPTION Hook the interface...

Страница 17: ...ty event to be correctly posted by the interface on the KNX bus the minimum time of that event must be greater than or equal to 3 seconds WARNING For details about programming contact technical assist...

Страница 18: ...ories to the module using the relevant connectors Insert the SIM into the slot c Attach module PXGPRS to the control unit board using the mounts provided in the package taking care that the IGSM conne...

Страница 19: ...ssary to set a Select GPRS from the types of connection b Select Connectivity GSM c Enter APN Access Point Name Usually telephone service providers publish this information on their websites d If nece...

Страница 20: ...e GSM module to a domestic WiFi network you must a Select WIFI from the types of connection b Select Connectivity WIFI c Deselect Access point mode so as to set the WiFi mode as Station d Enter SSID a...

Страница 21: ...people and sends the alarm message to the control unit then takes photographs of the areas and sends them to the GPRS module of the security system The PIR camera system is available in the following...

Страница 22: ...ters on the SIM provider s website d Select the telephone numbers on which to receive the notifica tion via MMS Sending via Email It is possible to enable sending emails with the information and pictu...

Страница 23: ...press the following keys in se quence 0 and 3 OPENING CLOSING CONTROL UNIT When the control unit is opened by removing the cover the system goes into alarm mode In order to avoid this first go into th...

Страница 24: ...button SW2 to store the re mote controls briefly press button A to store the key approach it to the reader The invitation will be repeated until the device to be associated is chosen Press the radio...

Страница 25: ...ILABLE KEYPAD MENU ADDRESS MENU ADDRESS 02 WAIT STEP 2 Enabling keypad in control unit 1 From a keypad that has already been correctly acquired usu ally keypad 1 go into the Technical Menu 2 With sele...

Страница 26: ...ss must be changed making it 02 or 03 The system cannot have radio receiver modules on the bus with identical addresses STEP 1 Address the expansion 1 On the expansion module set the address that you...

Страница 27: ...IO XX STEP 2 Operation on areas not available in EASY mode Defines the operation to be carried out on the areas switch on off 1 Staying in the Scenario Menu 2 With select AREA OPERATION 3 With set the...

Страница 28: ...GOING OUT SCENARIO B GOING TO BED Example If you wish to set the following scenarios on keypad 1 Key A GOING OUT Scenario Area 1 Area 2 and Area 3 Key B GOING TO BED Scenario Area 1 and Area 3 Key C...

Страница 29: ...IO L2 01 GOING TO BED SCENARIO L3 01 NO Programming inputs Basic parameters of an input 1 Go into the Technical Menu 2 With select INPUTS and press 3 With select the input to be set and press 4 With s...

Страница 30: ...Living Area immediate Input contact Perimeter delayed Input radar Living area path MODIFY INPUT 001 BEDROOM RADAR STATUS 001 ARMED TYPE 001 IMMEDIATE BALANCING 001 SINGLE BAL AREAS 001 DESCRIPTION 00...

Страница 31: ...en the radio inputs Select heading SELF LEARN and press the self learning button of the magnetic contact to complete the acquisition If the re ceiver has already been acquired pressing the key activat...

Страница 32: ...alarm events x x SABOTAGE sabotage events tampering etc x x TECHNICAL technical alarm events x x BURGLARY burglar alarm events x x SWITCHING ON OFF system switching on off events FAILURE failure event...

Страница 33: ...CODE 22 SWITCH OFF AREA NN 00 000 EXIT TEC MENU CODE 23 EXIT TECHNICAL MENU 3 302 00 000 RST BATTERY CODE 24 BATTERY TEST OK 1 302 00 000 BATTERY FAIL CODE 25 BATTERY TEST BAD 00 000 LOCAL CONN CODE...

Страница 34: ...ODE 73 DISABLING CODE NN 00 000 COD ENABLE CODE 74 ENABLING CODE NN 1 302 0 0 BATTERY KBD CODE 75 WL_KBD_BATT_EVENT NN 1 302 0 0 BATTERY SIR CODE 76 WL_SIREN_BATT_EVENT NN 1 137 0 0 SUPERVIS KBD CODE...

Страница 35: ...ware interface 2 Write the text of the common message in the Voice Message column 3 Play the text to check how it sounds some words may not convert correctly and may have to be adjusted with accented...

Страница 36: ...new key 1 Go into the Technical Menu 2 With select KEYS and press 3 With select SELECT KEY and press 4 With select the key to be learned and press 5 With select LEARN KEY and press 6 Place the key to...

Страница 37: ...s can be learned during first switch on of the control unit following the voice guide see section POWER ON CTR U or later via the technical menu as shown below Acquiring new remote control 1 Go into t...

Страница 38: ...On the PC set the password to access the control unit the same as the Technical Code 222222 which is factory set 2 Select the COM communication serial port Set the programming mode on the Control uni...

Страница 39: ...the keypad displays SETTING UP set Dip 2 to OFF 5 The words SETTING UP IN PROCESS appear on the keypad 6 At the end of setting up the control unit returns to displaying the system status 2 Press butto...

Страница 40: ...Italy 33079 Sesto al Reghena Pordenone Italy 39 0422 4940 39 0422 4941 39 0434 698111 39 0434 698434 English Manual code FA00464 EN ver 1 03 2017 CAME S p a The data and information shown in this manu...

Отзывы: