background image

ENGLISH

Page 

3

  - Manual code: 

FA00464-EN

 ver

1

 03/2017 © C

AME S.p.a. - The data and information shown in this manual ar

e t

o be consider

ed as subject t

o change at any time and without the need for any advance warning.

Particulars

Symbols and glossary

  This symbol shows the parts which describe safety issues 

   This symbol shows the parts which must be read with 

care 

 

Warning light constantly on 

 

Warning light off 

 

Warning light flashing 

INSTALLER: the person/firm responsible for designing, creating and 
programming the security alarm system 
USER: the person/people using the security alarm system 

Description of use

The PXC99W security alarm control unit has been designed to in-
crease security in both homes and service-sector businesses, even 
where the cabling for a wired system is particularly problematic 

 Any installation and use other than that specified in this 

manual is forbidden 

Security 

If designed correctly, the security alarm system guarantees a high 
level of security to the buildings to be protected and the users who 
will use it 
Some rules must be followed to ensure this is the case:

 The installation must be carried out by qualified, expert per-

sonnel and fully respect the regulations in force 

 Check the connections of the primary power supply and the 

relative connections to earth 

 Once the system is up and running, make sure the User has 

changed the factory User Code (123456) 

STANDARD EN 50131 - SPECIFIC RECOMMENDATIONS 

 To ensure that the system complies with standard EN 50131, 

it is very important to implement the following recommendations:

the acoustic signals (buzzer) of the readers cannot be deacti-

vated;

"Memory" type inputs must not be used;

inputs configured as "Switching on" comply only if they are 

controlled by devices with more than 10000 combinations;

notifications of failures of devices connected to the system are 

not required by the standard, but if a device is equipped with such 
notifications, it must be connected to the input showing as failed at 
the control unit;

the telephone dialler must be on;

a self-powered external siren must be present on the system to 

warn of any security breaches;

the command to force the arming of areas with open inputs 

must not be activated;

the number of alarms to auto-exclude an input must be set be-

tween 3 and 10;

the no power warning time must be set at 1 minute;

the battery test time must be set at a value higher than 5 min-

utes;

fast switch-on must not be enabled;

the stop communication when control unit switched off option 

must not be enabled;

Entry time 1 and Entry time 2 can be set at a maximum of 45 

seconds;

the system screening time must be set at a value ≤ 30 seconds;

the pre-arming test must be enabled 

Содержание PXC99W

Страница 1: ...SECURITY ALARM CONTROL UNIT INSTALLER MANUAL PXC99W FA00464 EN...

Страница 2: ...TION 15 ADDRESSING 15 ACCESSORIES PAG 16 PXGSM 16 CIRCUIT BOARD DESCRIPTION 16 INSTALLATION 16 PXLAN PXWEB LAN INTERFACES 16 CIRCUIT BOARD DESCRIPTION 16 INSTALLATION 16 PXKNX 17 CIRCUIT BOARD DESCRIP...

Страница 3: ...ary power supply and the relative connections to earth Once the system is up and running make sure the User has changed the factory User Code 123456 STANDARD EN 50131 SPECIFIC RECOMMENDATIONS To ensur...

Страница 4: ...ephone Tablet Modem Router Switch Local PC PXDGETH LAN dongle 1 Building automation system CAME Domotic 3 0 PXIPC01 Programming cable LAN network INTERNET RS485 bus PSTN line Internal connection Stand...

Страница 5: ...and twisted pair cable with a cross section of at least 2 x 0 5 mm for power supply and twisted pair 2 x 0 22 mm for data 2 x 0 5 mm for power supply and twisted pair 2 x 2 x 0 22 mm for data used to...

Страница 6: ...A and B Analysing the circuit made in this way you can see that the structure of the RS 485 bus is still linear entry exit DOUBLE BRANCH CABLING RS 485 CABLE Screened 2 x 1 5 mm twisted 2 x 0 22 mm C...

Страница 7: ...4 EN ver 1 03 2017 CAME S p a The data and information shown in this manual are to be considered as subject to change at any time and without the need for any advance warning CABLING WITH BUS AMPLIFIE...

Страница 8: ...II Insulation class Dimensions HxWxD mm 300x250x65 Case ABS RAL9003 IP Rating IP30 Weight kg 2 70 Scenarios 16 Radio inputs 99 Wired inputs in control unit 6 Type of inputs in control unit NC NA SB D...

Страница 9: ...eripherals connected 95mA with keypad backlight ing off 110mA with keypad back lighting on at maximum bright ness Power draw with control unit in alarm mode and PSTN on a call 155mA Description of cir...

Страница 10: ...f The output is protected by a 100 ohm resistor It can also be used to control sirens or other loads U2 U3 U4 PROGRAMMABLE OUTPUT Open Collector A short circuit at 12V CC with active output for a long...

Страница 11: ...s a general alarm output and is not programmable It follows the general alarm status and remains active for the programmed time Non self powered siren Self powered siren PSTN TELEPHONE LINE The PSTN t...

Страница 12: ...6 7 8 Areas partially on 9 Areas not ready 10 Areas off 10 11 12 13 DISPLAY ICONS Symbol Meaning CAME logo System armed System disarmed System partially armed Programming Events memory User menu or re...

Страница 13: ...d disabled Symbol Meaning Alarm memory Not ready for arming Generic power supply failure 230 V network power supply failure Battery failure PSTN line down GSM line down Serial connection local Etherne...

Страница 14: ...the keypad software version to be viewed Pressing twice in succession takes you out of the Keypad Menu If xx seconds pass without any action the keypad goes into STAND BY mode and after a further xx...

Страница 15: ...system man agement off constantly on flashing on rapidly slowly With the transponder reader you can view the system status through the signals provided by its LEDs as in the previous table Depending u...

Страница 16: ...ge For remote connection to the PXLAN and PXWEB interfaces the router connected to your home network must be configured see the relative instruction manual CIRCUIT BOARD DESCRIPTION Hook the interface...

Страница 17: ...ty event to be correctly posted by the interface on the KNX bus the minimum time of that event must be greater than or equal to 3 seconds WARNING For details about programming contact technical assist...

Страница 18: ...ories to the module using the relevant connectors Insert the SIM into the slot c Attach module PXGPRS to the control unit board using the mounts provided in the package taking care that the IGSM conne...

Страница 19: ...ssary to set a Select GPRS from the types of connection b Select Connectivity GSM c Enter APN Access Point Name Usually telephone service providers publish this information on their websites d If nece...

Страница 20: ...e GSM module to a domestic WiFi network you must a Select WIFI from the types of connection b Select Connectivity WIFI c Deselect Access point mode so as to set the WiFi mode as Station d Enter SSID a...

Страница 21: ...people and sends the alarm message to the control unit then takes photographs of the areas and sends them to the GPRS module of the security system The PIR camera system is available in the following...

Страница 22: ...ters on the SIM provider s website d Select the telephone numbers on which to receive the notifica tion via MMS Sending via Email It is possible to enable sending emails with the information and pictu...

Страница 23: ...press the following keys in se quence 0 and 3 OPENING CLOSING CONTROL UNIT When the control unit is opened by removing the cover the system goes into alarm mode In order to avoid this first go into th...

Страница 24: ...button SW2 to store the re mote controls briefly press button A to store the key approach it to the reader The invitation will be repeated until the device to be associated is chosen Press the radio...

Страница 25: ...ILABLE KEYPAD MENU ADDRESS MENU ADDRESS 02 WAIT STEP 2 Enabling keypad in control unit 1 From a keypad that has already been correctly acquired usu ally keypad 1 go into the Technical Menu 2 With sele...

Страница 26: ...ss must be changed making it 02 or 03 The system cannot have radio receiver modules on the bus with identical addresses STEP 1 Address the expansion 1 On the expansion module set the address that you...

Страница 27: ...IO XX STEP 2 Operation on areas not available in EASY mode Defines the operation to be carried out on the areas switch on off 1 Staying in the Scenario Menu 2 With select AREA OPERATION 3 With set the...

Страница 28: ...GOING OUT SCENARIO B GOING TO BED Example If you wish to set the following scenarios on keypad 1 Key A GOING OUT Scenario Area 1 Area 2 and Area 3 Key B GOING TO BED Scenario Area 1 and Area 3 Key C...

Страница 29: ...IO L2 01 GOING TO BED SCENARIO L3 01 NO Programming inputs Basic parameters of an input 1 Go into the Technical Menu 2 With select INPUTS and press 3 With select the input to be set and press 4 With s...

Страница 30: ...Living Area immediate Input contact Perimeter delayed Input radar Living area path MODIFY INPUT 001 BEDROOM RADAR STATUS 001 ARMED TYPE 001 IMMEDIATE BALANCING 001 SINGLE BAL AREAS 001 DESCRIPTION 00...

Страница 31: ...en the radio inputs Select heading SELF LEARN and press the self learning button of the magnetic contact to complete the acquisition If the re ceiver has already been acquired pressing the key activat...

Страница 32: ...alarm events x x SABOTAGE sabotage events tampering etc x x TECHNICAL technical alarm events x x BURGLARY burglar alarm events x x SWITCHING ON OFF system switching on off events FAILURE failure event...

Страница 33: ...CODE 22 SWITCH OFF AREA NN 00 000 EXIT TEC MENU CODE 23 EXIT TECHNICAL MENU 3 302 00 000 RST BATTERY CODE 24 BATTERY TEST OK 1 302 00 000 BATTERY FAIL CODE 25 BATTERY TEST BAD 00 000 LOCAL CONN CODE...

Страница 34: ...ODE 73 DISABLING CODE NN 00 000 COD ENABLE CODE 74 ENABLING CODE NN 1 302 0 0 BATTERY KBD CODE 75 WL_KBD_BATT_EVENT NN 1 302 0 0 BATTERY SIR CODE 76 WL_SIREN_BATT_EVENT NN 1 137 0 0 SUPERVIS KBD CODE...

Страница 35: ...ware interface 2 Write the text of the common message in the Voice Message column 3 Play the text to check how it sounds some words may not convert correctly and may have to be adjusted with accented...

Страница 36: ...new key 1 Go into the Technical Menu 2 With select KEYS and press 3 With select SELECT KEY and press 4 With select the key to be learned and press 5 With select LEARN KEY and press 6 Place the key to...

Страница 37: ...s can be learned during first switch on of the control unit following the voice guide see section POWER ON CTR U or later via the technical menu as shown below Acquiring new remote control 1 Go into t...

Страница 38: ...On the PC set the password to access the control unit the same as the Technical Code 222222 which is factory set 2 Select the COM communication serial port Set the programming mode on the Control uni...

Страница 39: ...the keypad displays SETTING UP set Dip 2 to OFF 5 The words SETTING UP IN PROCESS appear on the keypad 6 At the end of setting up the control unit returns to displaying the system status 2 Press butto...

Страница 40: ...Italy 33079 Sesto al Reghena Pordenone Italy 39 0422 4940 39 0422 4941 39 0434 698111 39 0434 698434 English Manual code FA00464 EN ver 1 03 2017 CAME S p a The data and information shown in this manu...

Отзывы: