+ - TC
TAMPER ALARM
5
6
②
①
250
300
197
25
78
125
125
ENGLISH
Page
10
- Manual code:
FA00464-EN
ver
.
1
03/2017 © C
AME S.p.a. - The data and information shown in this manual ar
e t
o be consider
ed as subject t
o change at any time and without the need for any advance warning.
• After disconnecting the grid power supply, remove the termi-
nal board's perspex protective cover, undoing the two screws
fastened to the transformer
①
• Connect the line and neutral 230V AC cable to the terminal
board terminals (the power supply cables must go into the rel-
evant pre-made hole
②
)
• Replace the terminal board's perspex protective cover, fasten-
ing it to the transformer with the two screws
U1 is a (freely programmable) output that provides a positive when
it is active:
•
U1 ON = 13 8 V DC
•
U1 OFF = not connected
It is factory-programmed as a TC to inhibit microwaves when the
system is off (U1 = OFF if at least one area is on or during exit
times; U1= ON if the system is totally off)
The output is protected by a 100 ohm resistor
It can also be used to control sirens or other loads
U2, U3, U4 PROGRAMMABLE OUTPUT (Open Collector)
A short circuit at 12V CC with active output for a long time may
lead to the protective resistor being broken
Non-self-powered siren
U2, U3, U4 are (freely programmable) Open Collector-type outputs
that provide a negative when they are active:
•
U2, U3, U4 ON = 0 V DC
•
U2, U3, U4 OFF = not connected
The outputs are protected by 100 ohm resistors
Outputs Cabling
PROGRAMMABLE OUTPUT U1
A short circuit to GND with active output for a long time may
lead to the protective resistor being broken
Wall mounting
Install the control unit far from access points and somewhere it is
hard to identify
Secure onto a suitable wall that can permanently support the con-
trol unit
Prepare the holes and channel for the cables to pass through before
installation
Use the 2 pre-made holes for attaching to the wall
Control Unit Power Supply
230V AC GRID POWER SUPPLY
Provide a suitable bipolar disconnection device (circuit
breaker), with a distance of more than 3 mm between the contacts,
for isolating the power supply