Addressing and learning peripherals
ACQUIRING KEYPADS
The system cannot have keypads with identical addresses
The control unit leaves the factory with keypad 1 enabled, which
corresponds to the local keypad
In order to connect a keypad on a Bus, given that they are all pro-
duced with the address 01, their address must be changed, making
it 02 or 03
The table below shows the steps to take for a new keypad to be
addressed and acquired by the control unit In the example Keypad
02 is being acquired
STEP 1: Assigning address to new keypad
1 The display of the keypad to be added to the system will show
NOT AVAILABLE
at switch-on;
2 Press and hold down button
(*)
of that keypad, until the
KEYPAD MENU
is displayed;
3 With the
(
▲
)
/
(
▼
)
buttons move to the
ADDRESS MENU
and press
(*)
;
4 With the
(
+
)
/
(
‒
)
buttons select
ADDRESS 02
, press
(*)
and
(#)
twice to exit, the keypad will display
WAIT...
*
▼
▲
▼
▲
*
*
#
#
NOT AVAILABLE
KEYPAD MENU
ADDRESS MENU
ADDRESS 02
WAIT...
STEP 2: Enabling keypad in control unit
1 From a keypad that has already been correctly acquired (usu-
ally keypad 1), go into the Technical Menu
2 With
(
▲
)
/
(
▼
)
select
SYSTEM
and press
(*)
3 With
(
▲
)
/
(
▼
)
select
MODIFY SYSTEM
and press
(*)
4 With
(
▲
)
/
(
▼
)
select
KEYPADS
5 With the number keys select the keypad to be enabled (
(#)
=
enabled,
(
‒
)
disabled), in our case press key
(2)
6 Press
(#)
to return to the
MODIFY SYSTEM
menu
*
▼
▲
▼
▲
▼
▲
*
#
2
SYSTEM 02
MODIFY
SYSTEM
MODIFY
SYSTEM
KEYPADS
#-
KEYPADS
##
ACQUIRING INSERTERS
The system cannot have readers with identical addresses
All the readers are produced with address 1 and the control units do
not have a reader enabled as a factory setting
The control unit sees the on-board keypad's reader as the reader of
the keypad itself, therefore the two readers that can be connected
by bus should have address 01 and/or 02
For a new reader to be addressed and acquired by the control unit
you must (example of adding reader 2):
STEP 1: Enabling readers in control unit
1 Go into the Technical Menu
2 With
(▲)
/
(▼)
select
SYSTEM
and press
(*)
3 With
(▲)
/
(▼)
select
MODIFY SYSTEM
and press
(*)
4 With
(▲)
/
(▼)
select
INSERTERS
5 Use the number keys to select the reader to be enabled (
#
=
enabled,
-
= disabled)
6 Press
(#)
to go back to the previous menu
*
*
SYSTEM 02
MODIFY
SYSTEM
▼
▲
▼
▲
INSERTERS
#-
▼
▲
INSERTERS
##
#
2