Open warning light
Barrier status warning.
F10
Open warning light
0 = Warning light on (default) - The light stays on when the boom is moving or open.
1 = Warning light flashing - The warning light flashes every half a second when the
boom is opening and remains on when the boom is open. The light flashes every
second when the boom is closing, and remains off when the boom is closed.
Sensor type
Set the type of control device.
F14
Sensor type
0 = Transponder
1 = Keypad (Default)
Electric lock
Choose the electric lock activation mode during boom manoeuvring.
Only for GPT40AGL, the default parameter is [3].
F17
Electric lock
OFF (Default)
1 = The electric lock is deactivated during barrier opening and remains deactivated
until the barrier is closed again.
3 = The electric lock is deactivated during boom opening or closing, but it is active
when the barrier is open or closed.
Light E1
Choose the type of device connected to the output.
F18
Light E1
0 =Flashing beacon (Default)
1 = Cycle light
The light remains off if an automatic closing time is not set.
Automatic closure
Set the time before automatic closure is activated, once the opening travel end point has been reached.
The function does not work if any of the safety devices are triggered when an obstacle is detected, or after a complete stop, or during a power outage.
F19
Automatic close
OFF (Default)
From 1 to 180 seconds
Pre-flashing time
Set the time for which the beacon is activated before each manoeuvre.
F21
Pre-flashing time
OFF (Default)
1 to 10 seconds
Opening speed
Set the opening speed (percentage of maximum speed).
The percentage values automatically adapt to the value entered in the function [Boom length].
F28
Opening speed
from 60% to 100% (Default 70%)