Maximum capacity of contacts
Device
Output
Power supply (V)
Power (W)
Accessories
10 - 11
24 AC
40
Additional light
10 - E1
24 AC
20
Flashing beacon
10 - E1
24 AC
20
Operator status warning light
10 - 5
24 AC
3
RGB LED strip
-
-
13,5
The sum of the connected accessories input must not exceed 40 W.
Command and control devices
1
Antenna with RG58 cable
2
Card reader
3
Transponder selector switch
4
Keypad selector
5
TEMPORARY STOP button (NC contact)
It stops the boom and excludes the automatic closing; after 15 seconds the barrier opens slowly.
If the contact is not used, it must be deactivated during programming.
6
Control device (NO contact)
OPEN ONLY function
When the [HOLD-TO-RUN] function is active, the control device must be connected during OPENING.
7
Control device (NO contact)
PARTIAL OPENING function
The contact must be used only for operators working in paired mode.
8
Control device (NO contact)
CLOSE ONLY function
When the [HOLD-TO-RUN] function is active, the control device must be connected during CLOSING.
9
Control device (NO contact)
OPEN-CLOSE function