P
age
19
- Manual
FA01440-EN
- 07/2020 - © C
AME S.p.A. - The contents of this manual may be changed at any time and without notice. - T
ranslation of the o
riginal instructions
PROGRAMMING
Programming button functions
3
2
1
1
ESC button
The ESC button is used to perform the operations described below.
Exit the menu
Delete the changes
Go back to the previous screen
Stop the operator
2
< > buttons
The <> buttons are used to perform the operations described below.
Navigate the menu
Increase or decrease values
Open or close the operator
3
ENTER button
The ENTER button is used to perform the operations described below.
Access menus
Confirm a choice
Getting started
Once the electrical connections have been made, proceed with commissioning. Only skilled and qualified staff may perform this operation.
Make sure that there are no obstacles in the way.
Power up and proceed with the operations indicated below.
F1
A1
A2
A3
Temporary stop
Boom length
Motor test
Travel calibration
After powering up the system, the first manoeuvre is always to open the gate. Wait for the manoeuvre to be completed.
Press the ESC button or STOP button immediately in the event of any faults, malfunctions, strange noises or vibrations, or unexpected behaviour in the
system.
If the display indicator LED flashes, this means that the electronic board has not yet been calibrated.
At the end of commissioning, check the correct operation of the device using the buttons near the display. Check that the accessories also work correctly.
Functions menu
Temporary stop
It stops the boom and excludes the automatic closing; after 15 seconds the barrier opens slowly.
F1
Temporary stop
OFF (Default)
ON
CX input
Associate a function with the CX input.
F2
CX input
OFF (Default)
C1 = Reopen while closing (photocells)
C4 = Obstacle standby (photocells)
C5 = Immediate closure at the travel end during opening
C7 = Reopen while closing (sensitive edges)
C9 = Immediate closure at the travel end during opening with obstacle standby during
closure
C10 = Immediate closure during opening with obstacle standby during closure (NO
contact)
r7 = Reopen while closing (sensitive edges with 8K2 resistor)