riginal instructions
MCBF
Models
GPX40
Std boom L = 3.05 m
10.000.000
Boom L = 4.05 m
-0 %
Boom L = 3.05 m with joint
-0 %
Boom L = 4.05 m with joint
-0 %
The GARD PX barrier has an innovative gearmotor in oil bath and has been designed to perform up to 10 million cycles. Thanks to its ultra-efficient
brushless motor, it is extremely reliable and requires very little maintenance.
The MCBF value relates to the barrier only and does not refer to any applicable accessories.
The percentages indicate how much the number of cycles should be reduced in relation to the type and number of accessories installed.
The installer is responsible for deciding on the type of intervention and the maintenance frequency, considering the use, installation site and number of daily
cycles.
If the barrier is not used for long periods of time, e.g. for installations at sites with seasonal closures, release the spring and remove the boom.
For information on correct installation and adjustments, please see the product installation manual.
For information on choosing products and accessories, please see our product catalogue.
If the barrier with an articulated joint is used, check that the moving parts of the joint are in good condition. Replace them if necessary.
Every 500,000 cycles and, in any case, every 6 months of operation, you must perform the maintenance work indicated below.
- Perform a general and complete check of the tightness of the nuts and bolts.
- Check the 45° boom balance and if necessary tension the balance spring, adjusting its traction operating on the hooking tie rods.
- Lubricate the spring when it is fully extended.
- Grease all of the moving mechanical parts.
- Check the warning and safety devices are working properly.
- Check that the microswitch connected to the cabinet cover is working correctly.
- Check the microswitch connected to the manual release is working properly, and the microswitch connected to the release accessories (optional).
- Check there are no oil leaks.
Every 1,000,000 cycles and, in any case, every 12 months of operation, you must perform the maintenance work indicated below.
- Replace the cushioned mechanical stops for boom adjustment (item code 88003-0096).
Every 2,500,000 cycles and, in any case, every 24 months of operation, you must perform the maintenance work indicated below.
- Replace the spring.