P
age
30
- Manual
FA01556-EN
- 07/2021 - © C
AME S.p.A. - The contents of this manual may be changed at any time and without notice. - T
ranslation of the o
riginal instructions
Motor test
Check the boom opens in the correct direction.
If the keys do not execute the commands correctly, invert the boom opening direction.
Configuration>
Motor settings
Motor test
The button > makes the motor turn in clockwise direction.
The button < makes the motor turn in an anticlockwise direction.
Travel calibration
Start the travel self-learning.
Configuration>
Motor settings
Travel calibration
Confirm? NO
Confirm? YES
Parameter reset
Restore factory settings except for the functions: [Radio decoding], [Boom length] and the settings related to travel calibration.
Information
Parameter reset
Confirm? NO
Confirm? YES
Manoeuvre counter
View the number of operator manoeuvres.
Total manoeuvres = Manoeuvres carried out since installation.
Partial manoeuvres = Manoeuvres carried out after the last one [Maintenance reset].
Information
Manoeuvre counter
Total manoeuvres
Partial manoeuvres
Maintenance reset
Reset the number of [Partial manoeuvres].
Information
Maintenance reset
Confirm? NO
Confirm? YES
FW version
Display the firmware version number and the GUI installed.
Information
FW version
Update the FW from USB
Update the firmware version of the device.
The function is displayed only when a USB memory stick is inserted.
Make sure the USB stick contains the firmware update file.
Information
Update the FW from USB
Confirm? NO
Confirm? YES
Temperature control
Control the temperature by activating a cartridge heater or a fan.
Configuration>
Functions
Temperature control.
Off
Heater (Default)
Fan