P
age
23
- Manual
FA01556-EN
- 07/2021 - © C
AME S.p.A. - The contents of this manual may be changed at any time and without notice. - T
ranslation of the o
riginal instructions
CY input
Associate a function with the CY input.
Configuration>
Wired safety devices
CY input
Deactivated (Default)
C1 = Reopen while closing (photocells)
C4 = Obstacle standby (photocells)
C5 = Immediate closure at the travel end during opening
C7 = Reopening during closure (sensitive edges)
C9 = Immediate closure at the travel end during opening with obstacle standby during
closure
C10 = Immediate closure during opening with obstacle standby during closure
C13 = Reopening during closure with immediate stop once the obstacle has been
removed, even with boom not in movement
R7 = Reopening during closure (sensitive edges with 8K2 resistor)
Open warning light
Barrier status warning. Device connected to the 10-5 output.
Configuration>
Manage lights
Open warning light
Warning light on (Default) - The light stays on when the boom is moving or open.
Warning light flashing - The warning light flashes every half a second when the boom
is opening and remains on when the boom is open. The light flashes every second
when the boom is closing, and remains off when the boom is closed.
Sensor type
Set the type of control device.
Manage users
Sensor type
Keypad
Transponder
Light E1
Choose the type of device connected to the output.
Configuration>
Manage lights
Light E1
Flashing beacon (Default)
Cycle lamp
The light remains off if an automatic closing time is not set.
Automatic closure
Set the time before automatic closure is activated, once the opening travel end point has been reached.
The function does not work if any of the safety devices are triggered when an obstacle is detected, after a complete stop, during a power outage or if
there is an error.
Configuration>
Times
Automatic close
Deactivated (Default)
From 1 to 180 seconds
Pre-flashing time
Set the time for which the beacon is activated before each manoeuvre.
Configuration>
Manage lights
Pre-flashing time
Deactivated (Default)
1 to 10 seconds