P
age
28
- Manual
FA01556-EN
- 07/2021 - © C
AME S.p.A. - The contents of this manual may be changed at any time and without notice. - T
ranslation of the o
riginal instructions
CZ input
Associate a function with the CZ input.
Configuration>
Wired safety devices
CZ input
Deactivated (Default)
C1 = Reopen while closing (photocells)
C4 = Obstacle standby (photocells)
C5 = Immediate closure at the travel end during opening
C7 = Reopening during closure (sensitive edges)
C9 = Immediate closure at the travel end during opening with obstacle standby during
closure
C10 = Immediate closure during opening with obstacle standby during closure
C13 = Reopening during closure with immediate stop once the obstacle has been
removed, even with boom not in movement
R7 = Reopening during closure (sensitive edges with 8K2 resistor)
Safety devices test
Check that the photocells connected to the inputs are operating correctly, after each opening and closing command.
Configuration>
Wired safety devices
Safety devices test
Deactivated (Default)
CX
CY
CZ
CX+CY
CX+CZ
CY+CZ
CX+CY+CZ
Hold-to-run
With the function active, the operator stops moving (opening or closing) when the control device is released.
When the function is active, it excludes all other control devices.
Configuration>
Functions
Hold-to-run
Deactivated (Default)
On
Obstacle with motor stopped
With the function active, the boom remains stopped if the safety devices detect an obstacle. The function activates with: closed boom, open boom or after a
complete stop.
Configuration>
Wired safety devices
Obst. with motor stopped
Deactivated (Default)
On