![Cambium PTP 450 Скачать руководство пользователя страница 210](http://html1.mh-extra.com/html/cambium/ptp-450/ptp-450_configuration-and-users-manual_3577514210.webp)
Compliance with safety standards
PTP 450 Configuration and User
pmp-0815 (August 2015)
6-11
The following calculation is based on the ANSI IEEE C95.1-1991 method, as that
provides a worst case analysis. Details of the assessment to EN50383:2002 can be
provided, if required.
Where:
Is:
S
power density in W/m
2
P
maximum average transmit power
capability of the radio, in W
G
total Tx gain as a factor, converted
from dB
d
distance from point source, in m
Rearranging terms to solve for distance yields:
2
4
.
d
G
P
S
S
G
P
d
.
4
.