Security planning
4-38
pmp-0815 (August 2015)
Security planning
This section describes how to plan for PTP 450 networks to operate in secure mode.
Isolating BHMs from the Internet
Ensure that the IP addresses of the BHMs in your network:
Are not routable over the Internet.
Do not share the subnet of the IP address of your user.
RFC 1918, Address Allocation for Private Subnets, reserves for private IP networks three
blocks of IP addresses that are not routable over the Internet:
/8 subnets have one reserved network, 10.0.0.0 to 10.255.255.255.
/16 subnets have 16 reserved networks, 172.16.0.0 to 172.31.255.255.
/24 subnets have 256 reserved networks, 192.168.0.0 to 192.168.255.255.
Managing module access by passwords
Adding a user for access to a module
From the factory, each module has a preconfigured administrator-level account in the
name
root
, which initially requires no associated password. This is the same
root
account
that you may have used for access to the module by
ftp
. When you upgrade a module:
An account is created in the name
admin
.
Both
admin
and
root
inherit the password that was previously used for access to the
module:
o
The
Full Access
password, if one was set.
o
The
Display-Only Access
password, if one was set and no Full Access password
was set.
If you use Wireless Manager, do not delete the root account from any module. If you use
an NMS that communicates with modules through SNMP, do not delete the root account
from any module unless you first can confirm that the NMS does not rely on the root
account for access to the modules.
Each module supports four or fewer user accounts, regardless of account levels. The
available levels are
ADMINISTRATOR, who has full read and write permissions. This is the level of the
root
and
admin
users, as well as any other administrator accounts that one of them
creates.
INSTALLER, who has permissions identical to those of ADMINISTRATOR except that
the installer cannot add or delete users or change the password of any other user.
TECHNICIAN, who has permissions to modify basic radio parameters and view
informational web pages.
GUEST, who has no write permissions and only a limited view of General Status tab.
The ability to view information of General Status tab can be controlled by the "Site
Information Viewable to Guest Users" under the SNMP tab.