Security planning
PTP 450 Configuration and User
pmp-0815 (August 2015)
4-51
SNMPv3 security level, Authentication and Privacy Protocol
The authentication allows authentication of SNMPv3 user and privacy allows for
encryption of SNMPv3 message. PTP 450 supports MD5 authentication and
CBC-DES privacy protocols.
SNMPv3 Read-Only and Read/Write User
The user can defined by configurable attributes. The attributes and default
values are:
Read-only user
o
Username = Canopyro
o
Authentication Password = authCanopyro
o
Privacy Password = privacyCanopyro
Read-write user (by default read-write user is disabled)
o
Username = Canopy
o
Authentication Password = authCanopy
o
Privacy Password = privacyCanopy
SNMPv3 Trap Configuration
The traps may be sent from radios in SNMPv3 format based on parameter
settings. It can be configured for Disabled, Enabled for Read-Only User, Enable
for Read/Write User.
The SNMPv3 statistics page may not be displayed properly with Google Chrome browser.
Some tables are missing in the SNMPv3 Statistics Page.
The SNMPv3 Data is present on the page, but it is not listed in tabular form.