Chapter 20: Ethernet Protocols (CLI)
Configuring G.8032 (CLI)
phn-3965_006v002
Page 20-5
Parameter
Input Type
Permitted Values
Description
erpi-id
Number
1-64
The ID of the ERPI for which you want to set
or delete the RPL owner.
SP
Number or
Variable
east
west
sub-ring
Specifies the service point you want to
designate as the RPL owner.
The following command sets the East service point as the RPL owner for ERPI 1:
root> ethernet g8032 set-rpl-owner erpi-id 1 SP east
The following command sets the Sub-Ring service point as the RPL owner for ERPI 20:
root> ethernet g8032 set-rpl-owner erpi-id 20 SP sub-ring
The following command removes the RPL owner for ERPI 1:
root> ethernet g8032 remove-rpl-owner erpi-id 1
Configuring Timers (CLI)
You can configure timers per ERPI to control the ERPI's switching and convergence parameters. The following
timers are available:
•
Wait to Restore (WTR) Timer
–
Defines a minimum time the system waits after signal failure is recovered
before reverting to idle state.
•
Guard Time
–
Prevents unnecessary state changes and loops.
•
Hold-Off Time
–
Determines the time period from failure detection to response.
To configure the WTR timer, enter the following command in root view:
root> ethernet g8032 set-wtr erpi-id <erpi-id> wtr <wtr>
To configure the guard time, enter the following command in root view:
root> ethernet g8032 set-guard-time erpi-id <erpi-id> guard-time <guard-
time>
To configure the hold-off, enter the following command in root view:
root> ethernet g8032 set-holdoff-time erpi-id <erpi-id> holdoff-time
<holdoff-time>
Table 259
G.8032 Timer Configuration CLI Parameters
Parameter
Input Type
Permitted Values
Description
erpi-id
Number
1-64
The ID of the ERPI for which you want to set
a timer.
wtr
Number
1-12
The minimum time (in minutes) the system
waits after signal failure is recovered before
reverting to idle state.
Содержание PTP 820 Series
Страница 1: ...User Guide ...
Страница 49: ...Chapter 1 Introduction Configuration Tips phn 3965_006v002 Page 1 3 ...
Страница 57: ...Chapter 1 Introduction Front Panel Description phn 3965_006v002 Page 1 11 Figure 5 SM Card and Cover ...
Страница 114: ...Chapter 2 Getting Started Changing the Management IP Address phn 3965_006v002 Page 2 19 10 Click Apply ...
Страница 162: ...Chapter 3 Configuration Guide System Configurations phn 3965_006v002 Page 3 4 ...
Страница 294: ...Chapter 4 Unit Management Upgrading the Software phn 3965_006v002 Page 4 19 5 Select FTP ...
Страница 357: ...Chapter 5 Radio Configuration Configuring and Viewing Radio PMs and Statistics phn 3965_006v002 Page 5 43 ...
Страница 371: ...Chapter 5 Radio Configuration Configuring and Viewing Radio PMs and Statistics phn 3965_006v002 Page 5 57 ...
Страница 678: ...Chapter 12 Alarm Management and Troubleshooting Performing Diagnostics phn 3965_006v002 Page 12 28 ...
Страница 713: ...Chapter 14 Getting Started CLI Configuring the Activation Key CLI phn 3965_006v002 Page 14 18 ...
Страница 731: ...Chapter 14 Getting Started CLI Operating in FIPS Mode CLI phn 3965_006v002 Page 14 36 ...
Страница 809: ...Chapter 17 Radio Configuration CLI Configuring and Viewing Radio PMs and Statistics CLI phn 3965_006v002 Page 17 20 ...
Страница 867: ...Chapter 18 Ethernet Services and Interfaces CLI Viewing Ethernet PMs and Statistics CLI phn 3965_006v002 Page 18 48 ...
Страница 1002: ...Chapter 22 Synchronization CLI Configuring 1588 Transparent Clock CLI phn 3965_006v002 Page 22 15 ...
Страница 1149: ...phn 3965_006v002 Page V Term Definition WRED Weighted Random Early Detection XPIC Cross Polarization Interference Cancellation ...