CS3000 User’s Guide
Calsense
49
b.
Navigate to High temperature and use +/- to change to desired temperature.
c.
Navigate to If low temp is crossed and use +/- to select desired action: Do nothing or
Generate an alert.
d.
Navigate to Low temperature and use +/- to change to desired temperature.
11.
Navigate to Conductivity tab.
a.
Navigate to If high EC point is crossed and use +/- to select desired action: Do nothing or
Generate an alert.
b.
Navigate to High Conductivity and use +/- to change the desired dS/m.
c.
Navigate to If low EC point is crossed and use +/- to select desired action: Do nothing or
Generate an alert.
d.
Navigate to Low Conductivity and use +/- to change the desired dS/m.
12.
When finished, press BACK to save changes, and return to Main Menu.
Unlinking Orphan Station Decoders
Sometimes, 2-station decoders are removed from the system. For example, if a decoder has been
damaged, it may need to be replaced with a new decoder. After removing a decoder and performing a
2-Wire discovery, the station(s) assigned to that decoder may be orphaned. This means the station can
no longer run until it is assigned to a new decoder.
When an orphaned station is detected following a discovery, the Unlink Orphan 2-Wire Stations menu
option appears on the 2-Wire dialog. This allows these stations to be unlinked from the missing decoder,
thereby making them available to assign to a new decoder.
To Unlink Orphan 2-Wire Stations (Figure 38):
1.
From Main Menu, navigate to
Setup
and select
2-Wire
. The 2-Wire dialog displays.
2.
Navigate to and select
Unlink Orphan 2-Wire Stations
. The Unlink Orphan 2-Wire Stations
screen displays.
3.
Navigate to the Station to unlink and and press
SELECT
to unassign the station from the
removed decoder.
4.
When finished, press
BACK
to save changes, and return to Main Menu.
Figure 38: Unlink 2-Wire Stations Screen