CS3000 User’s Guide
Calsense
31
Assigning Stations to 2-Wire Decoders
Once 2-Wire decoders have been discovered, you can assign a station numbers to each output on a
decoder. For a controller that has both 2-Wire and conventional wiring, the stations can be numbered
from 1-80 and will be preceded with a T, such as T24. For a controller no conventional station terminals,
stations can be numbered from 1-128 and do not have the T in front of them.
To edit the 2-wire Station Assignment screen (Figure 21):
1.
From Main Menu, navigate to
Setup
and select
2-Wire
. The 2-Wire dialog displays.
2.
Navigate to
Assign Stations to Discovered Decoders
. The Station Assignment screen
displays.
3.
Navigate to desired Decoder by serial number (S/N) and press
SELECT
.
4.
Navigate to Station under Output A (black wires) and use
+/-
to assign a station number to
selected decoder.
Note:
Soil Moisture Sensor decoders only have a single station output so will
only show Output A.
5.
To activate the valve, select
Turn ON to Locate
energize the solenoid attached to the decoder
output.
Note:
This does not energize the pump or master valve so, the valve may not irrigate.
6.
Repeat steps 4-5 for to assign a station to Output B (orange wires).
7.
Press
Next
or
Prev
to move through the list of decoders and repeat steps 4-6 to assign stations
to each output with a valve attached.
8.
When finished, press
BACK
to save changes, and return to Main Menu.
Figure 21: 2-Wire Station Assignment Screen