Close coupled centrifugal single-stage
pumps,
with flanged connections
(sizes EN 733)
NM, NMS
,
NM4, NMS4
OPERATING INSTRUCTIONS
SAFETY
Read these instructions carefully before in-
stalling or using the device.
The assembler and final user must carefully com-
ply with all applicable standards and laws, inclu-
ding local regulations. The manufacturer declines
any liability in the event of damage due to impro-
per use or use under conditions other than those
indicated on the serial plate and in these instruc-
tions. The device has been built in conformity
with the current European Community laws.
Symbol used:
This symbol indicates high voltage
hazard.
It
draws
attention
to
components or procedures that could
represent a potential danger to the
health and welfare of the operator.
This symbol is used to draw the
operator's attention to situations of
potential danger for people or for
operations that could cause damage to
the product.
Example plate pump
1. Operating conditions
Standard construction
- For clean liquids, without abrasives, non-explo-
sive, non-aggressive for the pump materials,
with a maximum temperature of 90°C.
- Maximum permissible working pressure up to
10 bar.
- Installation in well ventilated location protected
from the weather with a maximum ambient tem-
perature of 40°C.
The electric data marked on the label are referred
to the nominal power of the motor.
Rated motor power
NM
(S) (2900 1/min) up to
kW: 2,2
7,5
30 75
NM
(S)
4
(1450 1/min) up to kW: 7,5
30
75
Sound pressure dB (A)
max:
70
80
85 90
Starts per hour
max:
60
40
20 10
2. Transportation
The safe movement of the equipment is
on the user responsability and any lif-
ting operation must be carried out by a
suitably trained and qualified personnel.
Raise the pump-motor unit slowly (fig.1), making
sure it does not move from side to side in an un-
controlled way, to avoid the risk of imbalance and
tipping up.
3. Installation
These pumps must be installed with the rotor axis
horizontal and feet downwards.
Place the pump as close as possible to the suction
source (with consideration given to the NPSH value).
Provide space around the pump for motor ventila-
tion, to allow for checking of shaft rotation, for fil-
ling and draining the pump and to allow for collec-
tion of the liquid to be removed.
(fig. 1)
6
4.93.323
Made in Italy
MONTORSO
NM 50/16B/A
IE2-87
0705158995
H max/min 31/20 m
n 2900/min
XYXYRRY
IEC 60034-1
5,5kW (7,5Hp)
VICENZA
Made in Italy
MONTORSO
Q min/max 15/30 m
3
/h
0705158995
IP 54
n 2900/min
400∆/690Y V3~50Hz
%
100
75
50
cos
ϕ
0,84
0,78
0,67
η
87,5
88,1
87,4
V
400
400
400
10,8 / 6,2 A
S1 l.cl. F
S1 49kg
92kg
5,5kW (7,5Hp)
VICENZA
1
11
2
3
4
4
5
6
7
8
9
10
12
13
19
20
8
9
13
14
15
16
17
18
1 Type 1
2 Delivery
3 Head
4 Rated power
5 Supply voltage
6 Fréquence
7 Nom. motor current
8 Rotation speed rpm
9 Operation Duty
10 Insul. class
11 Certifications
12 Serial number
13 Weight
14 Notes
15 Voltage
16 % Load
17 Power factor
18 Efficiency
19 Protection
20 Efficiency Class
Example plate motor