GB
Page 42 / 136
I-MAT_Ed2 - Operating Instructions
17. Alarms
Code
Description
Causes
Er01
Blockage due to no water;
Failed to reach set-point.
No water in the suction tank.
The system stops and restarts itself automatically:
- One attempt every 10 minutes for 6 times
- One attempt every hour for 24 times
- One attempt every 24 hours for 30 times
Er02
Primary pressure transducer fault
Cable not connected, broken connection, transducer
faulty.
Er03
Secondary pressure transducer fault
Cable not connected, broken connection, transducer
faulty.
Er04
Blockage due to low supply voltage
Supply voltage lower than 330V
- The system automatically restart when the clamp
voltage is higher than 345V.
Er05
Blockage due to high rectified supply voltage
Supply voltage higher than 520V
- The system automatically restart when the clamp
voltage is lower than 520V.
Er06
Blockage due to overcurrent in the electro pump motor
Er07
Blockage due to unbalanced output phases
Er08
Blockage due to direct short circuit between the phases
of output terminals
Er09
Blockage due to missing output phases
Er10
Blockage due to internal overheating
Er11
Blockage due to overheating of the power module
Er12
Blockage due to exceeded of number of starts
Er13
Blockage due to missing/wrong setting of main
parameters
Er14
Blockage due to float switch 1 intervention
The system will restart after a time, defined in
parameter AP41, from the state variation of the float
switch.
Er15
Blockage due to float switch 2 intervention
The system will restart after a time, defined in
parameter AP43, from the state variation of the float
switch.
Er16
Internal Hardware error
Contact the technical assistance.
Er17
Not implemented
Er18
Cascade mode communication error
Check the RS485 connection.
Er19
Cascade expansion card failure
Cascade expansion card not connected or faulty
Содержание IMAT
Страница 17: ...IT I MAT_Ed2 Istruzioni originali Pagina 17 136 16 Elenco parametri di programmazione...
Страница 38: ...GB Page 38 136 I MAT_Ed2 Operating Instructions 16 Parameter table list...
Страница 59: ...D I MAT_Ed2 Betriebsanleitung Seite 59 136 16 Verzeichnis Programmierungsparameter...
Страница 80: ...F Page 80 136 I MAT_Ed2 Instructions pour l utilisation 16 Liste des param tres de programmation...
Страница 101: ...E I MAT_Ed2 Instrucciones de uso P gina 101 136 16 Lista par metros de programaci n...
Страница 109: ...RU I MAT_Ed2 C 109 136 3 4 3 5 ENTER 3 6 20 3 7 3 8 5 19 30 50 50 30 60 60 0 30 30 0...
Страница 110: ...RU C 110 136 I MAT_Ed2 4 4 1 10 4 2 4 3 4 4 5 X 5 1 25 X 6 6 1 i 6 2 20 1 1 6 3 20 1 2...
Страница 122: ...RU C 122 136 I MAT_Ed2 16...