ACCESSORY WIRING
CM9-2 INSTALL ATION AND OWNER MANUAL V.3.1 | 2023.06.01
PAGE 31
Receiver
Relay/Normal Open - Relay
Common - 24V-COM
12-24V DC - 24-VDC
Photocell Sensor
(Non-Calimet Brand)
Monitored Close - MON-CLOSE
Monitored Open - MON-OPEN
Common - 24V-COM
12-24VDC - 24-VDC
Fire Access Box
Use 14-20 gauge awg wire (not included) and splice (join) with the wite and black wires.
Common (White) - 24V-COM
N/O (Black) - OPEN/LOOP
Safety Edge Sensor
Calimet Brand - (CM9-934) is wireless and requires no wiring.
Other Brand - Use the MON-CLOSE or MON-OPEN input depending on if it’s monitoring the open or close
cycle. Use COMMON and MON-24VDC if the safety edge requires electricity.
Keypad
Calimet Brand - CM9-535 is wireless and requires no wiring but it’s optional.
Other Brand - Use a 20 gauge stranded electrical wire and connect using the following:
Normal Open/Relay - RELAY
Common - 24V-COM
12-24VDC - 24-VDC
Access Controllers/Intercoms
Use a 20 gauge stranded electrical wire and connect using the following.
Normal Open/Relay - RELAY
Common - 24V-COM
12-24VDC - 24-VDC
If it requires a dedicated normal Open/Normal Close input, use the OPEN/LOOP input. The CLOSE input
for Normal Close. The 24-VDC and 24V-COM can supply electricity to the intercom/access controller.