PREINSTALLATION
CM9-2 INSTALL ATION AND OWNER MANUAL V.3.1 | 2023.06.01
PAGE 05
Gate Structure
Confirm that the gate operator being installed is appropriate for the gate type, weight and size. The gate
should be mounted and moving freely. There should be a little resistance in the movement of the gate. the
gate & post must be suitable for being automated. Check that the structure is sufficiently strong & stable,
and that its dimensions and weights conform to those listed in the specifications table of this document.
Any worn or damaged gate hardware must be repaired or replaced before installing the gate operator.
Vehicular gates are to be constructed and installed in accordance with the ASTM F2200 contruction
standards.
Electricity
The CM9-2 is powered by 110v-120v AC power. IF you have not already done so, and you are not using
solar power, wire a waterproof outlet near the gate following proper safety standards for your area. we’re
recommended hire a state licensed electrician to perform all your wiring tasks as well as wire in the CM9-2
swing linear arm. Make sure your electrician takes into account the voltage drop involved in running many
feet of wire to your installation location. If an insufficient gauge of wire is used, the gate operator may have
insufficient power.
The gate operator must be disconnected from the power source before the installation. This also includes
gate operator accessories.