4.3 System Keys
Refer to the examples later in this chapter for more details on the use of these keys.
Shift
This is the blue, unlabeled key, which is shown as Shift in this
manual. Pressing this key accesses the alternate or shifted function
of a key (such as Error). The
Shift
annunciator is lit when this key is
pressed.
Local
Press to change the AC source's selected interface from remote
operation to local (front panel) operation. Pressing the key will have
no effect if the interface state is already Local, Local-with-Lockout,
or Remote-with-Lockout.
Address
Press to access the system address menu. This menu lets you
configure the AC source's interface and output mode (1Ø or 3Ø) for
3000iL and 4500iL only. Menu entries will be stored in nonvolatile
memory. Use
s
and
t
to scroll through the following command list.
Use
↑
and
↓
to scroll through the parameter list.
Display
Command Function
ADDRESS <value>
Set IEEE-488 address
INTF <char>
Select interface (GPIB or RS232)
BAUDRATE <char>
Set RS-232C baud rate (300 600 1200 2400
4800 9600)
PARITY <char>
Choose RS-232C message parity (NONE, EVEN
or ODD)
LANG <char>
Set language (SCPI or E9012)
NOUTPUTS <char>
Set number of output phases (1 or 3) for 3000iL
and 4500iL only
<value> = a numeric value
<char> = a character string parameter
Table 12 : Interface selection
Recall
Press to place the AC source into a previously stored state. You
can recall up to 16 (0 through 15) previously stored states.
Shift Error
Press to display the system error codes stored in the SCPI error
queue. This action also clears the queue. If there is no error in
the queue, 0 is displayed.
Shift Save
Press to store an existing AC source state in nonvolatile
memory. The parameters saved are listed under *SAV in the AC
source SCPI Programming Manual. You can save up to 16
states (0 through 15).
Содержание 3000iL
Страница 9: ...iL Series User Manual California Instruments Rev B ix page intentionally left blank...
Страница 10: ......
Страница 37: ...iL Series User Manual California Instruments Rev B 27...
Страница 84: ...iL Series User Manual 74 Rev B California Instruments Figure 21 Troubleshooting Diagram for No Output Present...
Страница 89: ...iL Series User Manual California Instruments Rev B 79 Figure 23 AC Power Source Block Diagram...
Страница 93: ...iL Series User Manual California Instruments Rev B 83 Figure 25 AC Input Board Parts Location...
Страница 94: ...iL Series User Manual 84 Rev B California Instruments Figure 26 Mother Board Parts Location...