iL Series User Manual
California Instruments
Rev B
55
5.2 IEC Measurement Specifications
(4801iL only)*
Parameter
Range
Accuracy (±)
Frequency
50 / 60 Hz
Current (Low range)
Fundamental
0 - 3.2 A
0.03 % + 3 mA
Harmonics 2 - 49
0.03 % + 2 mA + 0.2%/KHz
Current (High range)
Fundamental
0 - 32 A
0.05 % + 6 mA
Harmonics 2 - 49
0.05 % + 3 mA + 0.2%/KHz
Flicker
Compliant with IEC 868
Flicker perceptibility
Compliant with IEC 868
Reference Impedance
3 % (at 0.4
Ω
and 796
µ
H)
Synchronization
< 1 ppm
Current shunt burden
0 Volts
Current harmonic smoothing filter
1.5 sec
Pst Integration time
1, 5, 10 or 15 min
Sample rate
Window width
Acq.
overlap
50 Hz Operation
Rectangular measurement
window
Hanning measurement window
12.8 Khz
8.533 Khz
16 cycles
24 cycles
None
50 %
60 Hz Operation
Rectangular measurement
window
Hanning measurement window
15.360 KHz
7.680 KHz
16 cycles
32 cycles
None
50 %
* Specifications are in % of reading for 4801iL sinewave output with resistive load at
output frequency of 50 or 60 Hz in IEC mode of operation.
Table 36 : IEC Measurement Specifications
Содержание 3000iL
Страница 9: ...iL Series User Manual California Instruments Rev B ix page intentionally left blank...
Страница 10: ......
Страница 37: ...iL Series User Manual California Instruments Rev B 27...
Страница 84: ...iL Series User Manual 74 Rev B California Instruments Figure 21 Troubleshooting Diagram for No Output Present...
Страница 89: ...iL Series User Manual California Instruments Rev B 79 Figure 23 AC Power Source Block Diagram...
Страница 93: ...iL Series User Manual California Instruments Rev B 83 Figure 25 AC Input Board Parts Location...
Страница 94: ...iL Series User Manual 84 Rev B California Instruments Figure 26 Mother Board Parts Location...