FUNCTIONS MENU
Functions Menu
INSTRUMENT ADJUSTMENTS
To enter or exit
program mode
: Press
▲ ▼
together for 3 seconds
To scroll through
functions
: Press
▲
or
▼
To change
levels
or
options
: Press
✱ ▲
together or
✱ ▼
together
To view setpoint:
Press
✱
To increase setpoint:
Press
✱ ▲
together
To decrease setpoint:
Press
✱ ▼
together
To reset an alarm or fault condition:
Press
▲ ▼
together briefly
Notes:
If in difficulty by becoming “lost” in program mode, press
▲
and
▼
together for 3 seconds to return to display mode, check the
INSTRUMENT ADJUSTMENTS above and try again.
When in program mode, after 60 seconds of key inactivity the
display will revert to either
INPT
nonE
or, if the
initial configuration has been completed, the measured value.
Any settings already completed will be retained.
Main setpoint
(SP1)
Second setpoint
(SP2)
Process temperature (PV)
or setpoint (SP)
BAND
INT.T
DER.T
DAC
CYC.T
OFST
SP.LK
SPRR
SPRN
SOAK
SET.2
BND.2
CYC.2
LEVL 1
TUNE
Autotune or Park
oFF
; on; tunE; ParK; At.Sp
SP1 Prop band (gain)/hyst
0.1 deg to 25% sensor f/s
(
10°C/18°F
)
Integral time (reset)
Off; 0.1 to 60 min (
5 min
)
Derivative time (rate)
Off; 1 to 200 sec (
25 sec
)
Derivative approach
0.5 to 5.0 x bAnd (
1.5
)
Cycle time or on/off
On.off; 0.1 to 81 sec
(
20 sec
)
Offset (manual reset)
0
to 50% x bAnd
(
In.t = off
)
Setpoint lock (SP1)
Off
; on
Setpoint Ramp rate
0
to 9990 deg/hour
Ramp off/on
On;
off
; hold
Soak time
Off
; 0 to 1440 min
Adjust SP2 setpoint
+/– sensor full scale or
full scale
SP2 prop band/Gain/Hyst
0.1 deg to 100% sensor
f/s
(2°C/3.6°F)
SP2 Cycle on/off
On.off
; 0.1 to 81 sec
S P 1 S E T T I N G S
BAUD
DATA
DBUG
LEVL C
ADDR
Instrument address
0
to 255
Baud rate
1200: 2400: 4800:
9600
: 19k2
Data format
18n1
:18E1:18O1
Tx/Rx activity
Off
; on
C O M M S S E T T I N G S
P R O G R A M M E R S E T T I N G S
S P 2 S E T T I N G S
HAND
PL.1
PL.2
SP2.A
SP2.B
DISP
HI.SC
LO.SC
INPT
UNIT
LEVL 2
SP1.P
Read SP1 output %
0
to 100% read only
SP1 manual output %
0 to 100% proportional
mode only
Limit SP1 output %
100
to 0%
Limit SP2 output %
100
to 0%
Main SP2 mode
nonE
; dV
.hi; dV
.Lo; bAnd;
FS.hi; FS,Lo; Cool
Second SP2 mode
nonE
; LtCH; hold; Lt.ho;
nLin
Display resolution
1
or 0.1 degree
Set scale maximum
0.0
Sensor max to
sensor full scale
Set scale minimum
0.0
Sensor min to sensor
full scale
Select input sensor
nonE
Select display units
nonE
; oC; oF; bAr;
PSi; Ph; rh; SEt
M A N U A L A D J U S T M E N T S
S P 2 M O D E S
R A N G I N G
C O N F I G U R E I N P U T
SP2.D
BURN
REU.D
REU.L
SPAN
ZERO
CHEK
READ
TECH
UER
RSET
LEVL 3
SP1.D
SP1 output device
nonE
; rlY
; SSd
*
SP2 output device
nonE
; SSd; rlY
(read only)
*
Sensor burn-out
uP
.SC
; dn.SC; 1u.2d; 1d.2u
Reverse outputs
1r.2d
; 1d.2d; 1r
.2r; 1d.2r
Reverse O/P LEDs
1n.2n
; 1i.2n; 1n.2i; 1i.2i
Span adjustment
0.0
to 25% sensor f/s
Zero Adjustment
0.0
to 25%
sensor full scale
Set Monitor
Off
; on
Read Monitor
VAr; hi; lo deg
Read T
une Data
CtA; Ctb; Ct1; Ct2; Ct3;
Ct4; oS1; uS; oS2
Software version
Consult unit
RESET
nonE
; ALL
C O N F I G U R E O U T P U T
S A F E T Y S E T T I N G S
C A L I B R A T I O N
P E R F O R M A N C E D A T A
PROG
NO.AL
DIS.S
DER.S
LEVL 4
LOCK
Security lock
nonE
; LEV 3; LEV 2; ALL
Disable program auto-exit
Auto
; StA
Y
Disable -AL- alarm display
Off
; on
Display averaging
dir
; 1 to 32 (
6
)
Derivative sensitivity
0.1 to 1.0 x dEr
.t (
0.5
)
U S E R - P R O T E C T E D S E T T I N G S
PROGRAM ENTRY
Level C only visable
when COMMS
Option fitted
➔
QUICK START ENTRY
➔
KEY
▼ ▲
TO VIEW FUNCTIONS
KEY
✱ ▼
OR
✱ ▲
TOGETHER TO CHANGE LEVELS OR OPTIONS
Range of Adjustment shown in
red
under
description. If applicable, factory settings shown
in
bold
.
*
Note:
Dual Relay and Dual SSd Output Options
Models 3311/9311 and 3322/9322 have their
outputs pre-configured. (see page 22)
A3