A3486 3Phase 400Vac to 2x2kW/1x4kW 48Vdc
08/10/2007
10
NPO:
Filename:
Number of pages:
Page:
00120/04:A3486.MUTx/10 A3486_REV10.DOC
35
32
ItemID
Data Type
Access
Description
PowerSupplyName.BoardXX.Chan0.Rel String
R
Board firmware release
PowerSupplyName.BoardXX.Chan0.Tracking boolean
R Tracking
status
PowerSupplyName.BoardXX.Chan0.Tracking#CoOpen
string
R
Tracking open label
PowerSupplyName.BoardXX.Chan0.Tracking#CoClose
string
R
Tracking close label
PowerSupplyName.BoardXX.Chan0.12VPwS boolean
R 12VPS
status
PowerSupplyName.BoardXX.Chan0.12VPwS#CoOpen
string
R
12VPS open label
PowerSupplyName.BoardXX.Chan0.12VPwS#CoClose
string
R
12VPS close label
PowerSupplyName.BoardXX.Chan0.StatusIn boolean
R StatusIn
status
PowerSupplyName.BoardXX.Chan0.StatusIn#CoOpen
string
R
StatusIn open label
PowerSupplyName.BoardXX.Chan0.StatusIn#CoClose
string
R
StatusIn close label
PowerSupplyName.BoardXX.Chan0.Sync boolean
R
Sync
status
PowerSupplyName.BoardXX.Chan0.Sync#CoOpen
string
R
Sync open label
PowerSupplyName.BoardXX.Chan0.Sync#CoClose
string
R
Sync close label
PowerSupplyName.BoardXX.Chan0.HVSync boolean
R HVSync
status
PowerSupplyName.BoardXX.Chan0.HVSync#CoOpen
string
R
HVSync open label
PowerSupplyName.BoardXX.Chan0.HVSync#CoClose
string
R
HVSync close label
PowerSupplyName.BoardXX.Chan0.RemBdName string
R
Board
name
4.2.2
Output Channel OPC Items
This chapter describes the items which are available for the control of the power supply
channels.
The
Name
item allows to assign to the channel a symbolic name.
The
V0set
item allows to set V0.
A read access to the
V0set#EU
item returns a string with the V0set Engineering Units.
A read access to the
V0set#HighEU
item returns the highest possible V0set value.
A read access to the
V0set#LowEU
item returns the lowest possible V0set value.
The
I0set
item allows to set I0.
A read access to the
I0set#EU
item returns a string with the I0set Engineering Units.
A read access to the
I0set#HighEU
item returns the highest possible I0set value.
A read access to the
I0set#LowEU
item returns the lowest possible I0set value.
The
Trip
item allows to program the trip time.
A read access to the
Trip#EU
item returns a string with the Trip Engineering Units.
A read access to the
Trip#HighEU
item returns the highest possible Trip value.
A read access to the
Trip#LowEU
item returns the lowest possible Trip value.
The
SVMax
item allows to set the software voltage limit.
A read access to the
SVMax#EU
item returns a string with the SVMax Engineering Units.
A read access to the
SVMax#HighEU
item returns the highest possible SVMax value.
A read access to the
SVMax#LowEU
item returns the lowest possible SVMax value.
The
VMon
item returns back the VMon value.
A read access to the
VMon#EU
item returns a string with the VMon Engineering Units.
A read access to the
VMon#HighEU
item returns the highest possible VMon value.
A read access to the
VMon#LowEU
item returns the lowest possible VMon value.