2.2
Channel Characteristic Table
Table 2.1 – Technical specifications of the A3486 48 V Power Source
Packaging
19"-wide, 3U-high Euro-mechanics rack;
Depth: 50 cm.
Polarity
positive
AC input
3-phase 400 V / 50 Hz (see label below)
DC input
2A @ 48V (see label below)
Output Voltage
44 ÷ 52 V adjustable via software
Max. Output Power
4000 W
Max. Input Power
5000 W
Voltage Ripple
<100mVpp measured on 10Hz to 20MHz bandwidth
Voltage Monitor vs. Output Voltage Accuracy:
max. ±0.5%
Voltage Set vs. Output Voltage Accuracy:
max. ±0.5%
Current Monitor vs. Output Current Accuracy:
± 1A ± 2% of reading
Current Set vs. Output Current Accuracy:
± 1A ± 2% of setting
Fig. 2.2 – Back Panel Label