(Test continued)
36
C7000 & 7000ER Battery Analyzer V3.5
Option
Description
IF Total Capacity < 5%
If the capacity during the last discharge cycle is
less than 5%, go to the True statement.
Otherwise the False statement is selected.
IF Total Capacity > 5% If the capacity during the last discharge cycle is
greater than 5%, go to the True statement.
Otherwise the False statement is selected.
IF User Defined Timeout
If the time period set in Cycle 1 or Cycle 2 has
expired before the battery is fully charged,
discharged or reconditioned, go to the True
statement. Otherwise the False statement is
selected.
For Trickle Charge and Rest, the program will
proceed to the True statement only.
IF Loop Count < Max
If the number of cycle (the loop count) is less
than the value set in ’THEN REPEAT 0 times’ of
the True statement or ’ELSE REPEAT 0 times’
in the False statement, go to the True
statement. Otherwise the False statement is
selected.
IF Loop Count > Max
If the number of cycle (the loop count) is more
than the value set in ’THEN REPEAT 0 times’ of
the True statement or ’ELSE REPEAT 0 times’
in the False statement, go to the True
statement. Otherwise the False statement is
selected.
Содержание C7000
Страница 1: ...C7000 C7000ER Battery Analyzer User s Manual...
Страница 2: ...This page is blank...