56
C7000 & 7000ER Battery Analyzer V3.5
Detail
Global
Possible Reason(s) / Solution(s)
Charge timeout
FAIL 144
Charge time has exceeded the expected value for the
battery. Check that the mAh rating of the battery matches
the C-Code mAh setting. The Charge rate in the Extended
C-Code may have to be raised.
Charge wait
CHG WAIT
Station is on hold until sufficient power is available. This is
normal if large batteries are being serviced. Service will
automatically resume when sufficient power is available to
the station.
Charging
CHARGE
Battery is being charged normally.
Chrg complete temp
rise
WARNING
Battery is being charged normally but temperature is rising
rapidly towards its end of charge state. Wait until
processing is complete. An appropriate WAIT code may
appear until the battery has cooled before the next process
begins. The Charge rate in the Extended C-Code may
have to be lowered. Observe battery performance. The
battery may be old.
For non OEM battery, turn off temperature sensing.
Current rise
WARNING
For SLA only. Battery current suddenly increased as the
End of Charge condition was achieved. If the battery is a
Hawker cell, use the Hawker C-Code settings (refer to
Default Settings for Extended C-Codes). Allow the
station to complete service.
Cycle resumed
RESUMED
Power resumed or the battery is re-inserted into the
adapter.
D
Discharge current low
FAIL 162
The analyzer is not able to discharge the battery. Very low
values of current (< 50mA) are displayed on the analyzer
before this code appears. See code 160, Bad fuses or
driver.
Discharge cycle
complete
END
CYCLE
Discharge cycle completed. Program is going into the next
step.