ATENA - DUKE - SABA - MITHOS
36
Fig. 126 - Remove the cap
Fig. 127 - Unscrew the screws
Fig. 128 - Remove the fume diverter
• Vacuum the blades of the fume extraction fan (see
Fig. 129
).
• After cleaning, repeat the operation in reverse making sure the gasket is intact and efficient: if necessary, have it replaced by
an authorised technician.
Fig. 129 - Vacuum out the ash
7.6
ROOM FAN CLEANING
Clean every the year the room fan from ash or dust which can cause a blade unbalance and a greater noise.
Fig. 130 - Room fan cleaning
Fig. 131 - .
• Unscrew the side screws. (see dedicated chapters).
• Remove dust build-up using a brush or a vacuum cleaner (see
Fig. 130
Fig. 131
).
8
IN CASE OF ANOMALY
8.1
PROBLEM SOLVING
Before of every Authorized Technician intervention, the same Technician has the duty to check if the parame-
ters of the mother board correspond to those of the table you own.