25
EASY - SWEET
3
EN
•
After 5 minutes from the beginning of the switch-off procedure.
12.15
SLEEP FUNCTION (MAIN MENU)
The sleep function is activated only when the boiler is switched on and allows to quickly set a time at which the
product must switch off.
To set the Sleep function act as follows:
•
Enter MENU
•
Scroll to SLEEP with the <> arrows
•
Press Menu
•
With the + - keys adjust the desired shutdown time.
The panel proposes a shutdown time of 10 minutes from the current time, adjustable with key 4 until the next day
(I can therefore delay the shutdown for up to a maximum of 23 hours and 50 minutes).
Fig. 39 - Sleep
If the SLEEP function is active with the TIMER active the first has priority over the latter, therefore the boiler will not
switch off at the time set on the timer but instead by the time established by the sleep function, even if later than
the time set on the timer.
12.16
PELLETS RECIPE (SEE SECTION J )
This function is for adapting the stove to the pellets that are being used. In fact, as there are several types of
pellets on the market, boiler operation is extremely variable depending on the fuel quality. In the event the
pellets tend to clog the brazier due to an excessive load of fuel or in the event the flame is always high even at
low powers and, vice versa if the flame is low one can decrease/increase the amount of pellets in the brazier:
The available values are:
-30= 30% reduction with respect to the default setting.
-25= 25% reduction with respect to the default setting.
-20= 20% reduction with respect to the default setting.
-15 = 15% reduction with respect to the default setting.
-10= 10% reduction with respect to the default setting.
-5= 5% reduction with respect to the default setting.
0= No variation.
+5= 5% increase with respect to the default setting.
+10 = 10% increase with respect to the default setting.
+15 = 15% increase with respect to the default setting.
12.17
SMOKE RPM VARIATION (SEE SECTION I SETTINGS MENU PAGE 20)
If the installation presents difficulties for smoke evacuation (no draught or no pressure in the duct), the smoke
and ash expulsion speed can be increased. This change resolves all the potential problems related to pellets
clogging in the brazier and deposits forming at the bottom of the brazier itself caused by poor quality fuel or fuel
that produces a lot of ashes. The values available are from -27% to +27% with variations of 3 points at a time. The
variation in negative can be used in case the flame is too low.
12.18
CHIMNEY SWEEP FUNCTION (FOR MAINTENANCE TECHNICIANS ONLY) - SEE SECTION K
SETTINGS MENU PAGE 20
This function can be activated only when the boiler is on and with power output and heating operation power
with parameters P5, with fan (if present) in V5. Any loading/smoke ventilation percentage corrections must
be taken into account. This status lasts 20 minutes, the countdown is displayed on the panel. At any time the
technician can interrupt this stage by quickly pressing the on/off key.
12.19
STOVE CALIBRATION AND DEPRESSION MEASUREMENT
This stove has a pickup point positioned on the tank in order to measure the depression of the combustion
chamber and verify its proper operation.
To do this, proceed as follows:
•
Unscrew the nut at the back of the stove (see
Fig. 40 page 26
).
•
Connect a digital pressure switch with a tube to detect the depression (see
Fig. 41 page 26
).
•
Load the feed screw via appropriate function.
•
Start the stove and set "Fire" at power 1 (the start of this stove lasts from 8 to 10 minutes to ensure minimum
draught).
•
Compare the read values with those on the table.
•
Change power every 10 minutes and wait for it to stabilise.
•
Access the user menu and, if necessary, change the parameters.