EASY - SWEET
3
EN
LEGEND
Fig. 7 page 10
2
≥ 0,3 mt
3-3
Sectional view
4
Shield grid
5
Curve inlet to turn downwards
•
Insert the N fitting on the I air intake pipe
•
Connect N with Q using a flexible or stiff tube with a diameter of 60 mm and a maximum length of 2 metres
(see
Fig. 8 page 11
).
Fig. 8 - Connections
How to connect to the stove in the sealed chamber with concentric system:
•
Insert the N fitting into the I air intake pipe (see
Fig. 9 page 11
and
Fig. 10 page 11
). Connect N to Q using
a flexible tube which can resist a temperature of 100°C (a flexible aluminium tube is recommended).
•
Maximum height for the installation of a vertical exhaust flue (roof) HV = 6 mt (see
Fig. 11 page 11
).
•
Maximum height for the installation of a horizontal exhaust flue (wall) HO = 2.6 mt (see
Fig. 11 page 11
).
Fig. 9 - Flexible tube
Fig. 10 - Connections
Fig. 11 - Flue connections
LEGEND
Fig. 10 page 11 - Fig. 11 page 11
I
Combustion air intake with a diameter of 40 mm
N
Rubber fitting with a diameter of 40/60 mm
R
Flexible aluminium tube
Q
Coaxial pipe air combustion connection
Y
Coaxial pipe air combustion intake
HO
Height of coaxial flue with wall/horizontal exhaust
HV
Height of coaxial flue with roof/vertical exhaust
9.10
CHIMNEY FLUE CONNECTION
Your pellet stove works through a fume draught forced by a fan. It is obligatory to check that all pipes are
realized in compliance with the following regulation on material selection: EN 1856-1, EN 1856-2 e UNI/TS 11278.
All must be effected by specialized personnel or companies as provided by UNI 10683:2012.
•
The connection between the appliance and the chimney flue should be short in order to favor the draught