12
EASY - SWEET
3
EN
and to avoid condensation in the pipes.
•
The fume conduit should be equivalent or longer than the outlet joint ones (Ø 80 mm).
•
Some stove models are endowed with a lateral and/or back exhaust. Check that the unused exhaust is
sealed with the plug given with standard equipment.
SYSTEM TYPE
Ø80 mm PIPE
Ø100 mm PIPE
Minimum vertical length
1,5 mt
2 mt
Maximum length (with 1 union)
6,5 mt
10 mt
Maximum length (with 3 unions)
4,5 mt
8 mt
Maximum number of unions
3
3
Level section (minimum inclination 3%)
2 mt
2 mt
Installation at a height above 1200 m a.s.l.
NO
Obligatory
•
Use a plate pipe for stoves of Ø80 mm or Ø100 mm depending on the type of system and with silicone gaskets.
•
It is forbidden to use metal, fibre cement or aluminium flexible pipes.
•
For change of direction it is obligatory always to use a union (with angle > 90°) with inspection plug which
enables an easy periodic cleaning of the pipes.
•
Please assure you that after the cleaning the inspection plugs are sealed with its efficient gasket.
•
It is forbidden to connect more appliances to the same fume conduit.
•
It is forbidden to convey in the same fume conduit exhausts from overhanging cooker hoods.
•
It is forbidden to exhaust flue gases directly from the wall towards the outside and closed spaces also at open
top.
•
It is forbidden to connect any other appliance (wood stoves, cooker hoods, boilers, etc...).
•
The fume conduit must be placed at a distance of minimum 500 mm from flammable or heat-susceptible
components.
9.11
EXAMPLES OF CORRECT INSTALLATION
Fig. 12 - Example 1
LEGEND
Fig. 12 page 12
1
Insulating material
2
Reduction from Ø100 to Ø80 mm
3
Inspection plug
4
Minimum safety distance = 0,5 mt
•
Chimney flue installation Ø100/120 mm with an enlarged drilling for pipe transit.