36
EASY - SWEET
3
EN
PROBLEM
CAUSE
SOLUTION
INTERVENTION
The stove's smoke
duct produces
condensation
Low smoke
temperature
Check that the flue is not clogged.
Increase stove power to minimum (pellet drop and fan revs).
Install condensation collection cup.
16
TECHNICAL DATAS
16.1
REPAIR INFORMATION
Now we give some instructions for the Authorized Technician to take into consideration to have access to stove
mechanical components.
•
For fuse replacement in the electric socket which stands on the back of the stove, extract the fuses to change
with the aid of a screwdriver for opening the shutter (see
Fig. 61 page 36
).
Fig. 61 - Shutter with fuses to remove
Proceed as follows:
•
Remove the sides (see the dedicated chapters).
•
After these operations you can have access at the following components: geared motor, ignition plug,
ambient fan, fume fan, ambient probe, fume probe, thermostat, electronic board, pressostat.
•
For cleaning or replacemente of the auger it is necessary to unscrew the three bolt of the geared motor and
to extract it, unscrew the two screws lying under the geared motor of the auger, remove the hand rejector
inside the hopper and then unscrew the inner bolt of the auger.
•
To assembly proceed at the contrary.